Variation of zeta-potential with temperature in fused-silica capillaries used for capillary electrophoresis

Christopher Evenhuis, Rosanne Guijt, Miroslav Macka, Philip Marriott, Paul Haddad

Research output: Contribution to journalArticleResearchpeer-review

35 Citations (Scopus)

Abstract

The temperature variation of electroosmotic mobility corrected for the effects of Joule heating (mu(EOF)(0)) was employed to investigate the variation of the zeta-potential Q with temperature in fused-silica capillaries. Experimentally determined values for increased at 0.39 per degrees C, a rate that is about four to five times smaller than reported previously. Experimentally determined values of were directly proportional to the absolute temperature although values were also influenced slightly by changes to the dielectric constant. It was found that the effective charge density at the inner surface of the capillary was independent of temperature.
Original languageEnglish
Pages (from-to)672 - 676
Number of pages5
JournalElectrophoresis
Volume27
Issue number3
DOIs
Publication statusPublished - 2006
Externally publishedYes

Cite this