TY - JOUR
T1 - Validation of Two Screening Tools for Detecting Delirium in Older Patients in the Post-Anaesthetic Care Unit
T2 - A Diagnostic Test Accuracy Study
AU - Aldwikat, Rami K.
AU - Manias, Elizabeth
AU - Holmes, Alex
AU - Tomlinson, Emily
AU - Nicholson, Patricia
N1 - Funding Information:
This research received no specific grant from any funding agency in the public, commercial or not-for-profit sectors.
Publisher Copyright:
© 2022 by the authors.
PY - 2022/12
Y1 - 2022/12
N2 - (1) Background: Delirium is a common complication among surgical patients after major surgery, but it is often underdiagnosed in the post-anaesthetic care unit (PACU). Valid and reliable tools are required for improving diagnoses of delirium. The objective of this study was to evaluate the diagnostic test accuracy of the Three-Minute Diagnostic Interview for Confusion Assessment Method (3D-CAM) and the 4A’s Test (4AT) as screening tools for detection of delirium in older people in the PACU. (2) Methods: A prospective diagnostic test accuracy study was conducted in the PACU and surgical wards of a university-affiliated tertiary care hospital in Victoria, Australia. A consecutive prospective cohort of elective and emergency patients (aged 65 years or older) admitted to the PACU were recruited between July 2021 and December 2021 following a surgical procedure performed under general anaesthesia and expected to stay in the hospital for at least 24 h following surgery. The outcome measures were sensitivity, specificity positive predictive value and negative predictive value for 3D-CAM and 4AT. (3) Results: A total of 271 patients were recruited: 16.2% (44/271) had definite delirium. For a diagnosis of definite delirium, the 3D-CAM (area under curve (AUC) = 0.96) had a sensitivity of 100% (95% CI 92.0 to 100.0) in the PACU and during the first 5 days post-operatively. Specificity ranged from 93% (95% CI 87.8 to 95.2) to 91% (95% CI 85.9 to 95.2) in the PACU and during the first 5 days post-operatively. The 4AT (AUC = 0.92) had a sensitivity of 93% (95% CI 81.7 to 98.6) in the PACU and during the first 5 days post-operatively, and specificity ranged from 89% (95% CI 84.6 to 93.1) to 87% (95%CI 80.9 to 91.8) in the PACU and during the first 5 days post-operatively. (4) Conclusions: The 3D-CAM and the 4AT are sensitive and specific screening tools that can be used to detect delirium in older people in the PACU. Screening with either tool could have an important clinical impact by improving the accuracy of delirium detection in the PACU and hence preventing adverse outcomes associated with delirium.
AB - (1) Background: Delirium is a common complication among surgical patients after major surgery, but it is often underdiagnosed in the post-anaesthetic care unit (PACU). Valid and reliable tools are required for improving diagnoses of delirium. The objective of this study was to evaluate the diagnostic test accuracy of the Three-Minute Diagnostic Interview for Confusion Assessment Method (3D-CAM) and the 4A’s Test (4AT) as screening tools for detection of delirium in older people in the PACU. (2) Methods: A prospective diagnostic test accuracy study was conducted in the PACU and surgical wards of a university-affiliated tertiary care hospital in Victoria, Australia. A consecutive prospective cohort of elective and emergency patients (aged 65 years or older) admitted to the PACU were recruited between July 2021 and December 2021 following a surgical procedure performed under general anaesthesia and expected to stay in the hospital for at least 24 h following surgery. The outcome measures were sensitivity, specificity positive predictive value and negative predictive value for 3D-CAM and 4AT. (3) Results: A total of 271 patients were recruited: 16.2% (44/271) had definite delirium. For a diagnosis of definite delirium, the 3D-CAM (area under curve (AUC) = 0.96) had a sensitivity of 100% (95% CI 92.0 to 100.0) in the PACU and during the first 5 days post-operatively. Specificity ranged from 93% (95% CI 87.8 to 95.2) to 91% (95% CI 85.9 to 95.2) in the PACU and during the first 5 days post-operatively. The 4AT (AUC = 0.92) had a sensitivity of 93% (95% CI 81.7 to 98.6) in the PACU and during the first 5 days post-operatively, and specificity ranged from 89% (95% CI 84.6 to 93.1) to 87% (95%CI 80.9 to 91.8) in the PACU and during the first 5 days post-operatively. (4) Conclusions: The 3D-CAM and the 4AT are sensitive and specific screening tools that can be used to detect delirium in older people in the PACU. Screening with either tool could have an important clinical impact by improving the accuracy of delirium detection in the PACU and hence preventing adverse outcomes associated with delirium.
KW - delirium
KW - diagnostic accuracy
KW - older people
KW - post-anaesthetic care unit
KW - screening tools
UR - http://www.scopus.com/inward/record.url?scp=85143680662&partnerID=8YFLogxK
U2 - 10.3390/ijerph192316020
DO - 10.3390/ijerph192316020
M3 - Article
C2 - 36498093
AN - SCOPUS:85143680662
SN - 1661-7827
VL - 19
JO - International Journal of Environmental Research and Public Health
JF - International Journal of Environmental Research and Public Health
IS - 23
M1 - 16020
ER -