TY - JOUR
T1 - Utilizing a Low-Cost Air Quality Sensor
T2 - Assessing Air Pollutant Concentrations and Risks Using Low-Cost Sensors in Selangor, Malaysia
AU - Khaslan, Zaki
AU - Nadzir, Mohd Shahrul Mohd
AU - Johar, Hamimatunnisa
AU - Siqi, Zhang
AU - Sulong, Nor Azura
AU - Mohamed, Faizal
AU - Majumdar, Shubhankar
AU - Suris, Fatin Nur Afiqah
AU - Hawari, Nor Syamimi Sufiera Limi
AU - Borah, Jintu
AU - Gee, Maggie Ooi Chel
AU - Wahab, Muhammad Ikram A.
AU - Bakar, Mohd Aftar Abu
AU - Ariff, Noratiqah Mohd
AU - Japeri, Ahmad Zia Ul Saufie Mohamad
AU - Nor, Mohd Fadzil Firdzaus Mohd
AU - Rabuan, Utbah
AU - Ali, Sawal Hamid Md
AU - Murugan, Brentha
AU - Cayetano, Mylene G.
N1 - Funding Information:
We would like to thank the community of Olak Lempit in Banting, Selangor for allowing us to perform air sampling in Olak Lempit. The study is supported by Ministry of Science, Technology & Innovation of Malaysia (MOSTI): Technology Development Fund 1(TeD 1) with grant number TDF04211364 led by Prof Dr. Mohd Talib Latif. In addition, Shubhankar Majumdar want to give credit to the ASEAN-India Science and Technology Collaboration (AISTIC) Funding from the Department of Science and Technology, India (CRD/2020/000320) for providing financial supports for sensors installation.
Publisher Copyright:
© The Author(s), under exclusive licence to Springer Nature Switzerland AG 2024.
PY - 2024/4
Y1 - 2024/4
N2 - This study delves into nocturnal air quality, focusing on carbon monoxide (CO), nitrogen dioxide (NO2), surface ozone (O3), and particulate matter (PM2.5), in contrasting areas of Banting, Selangor: the rural-industrial Olak Lempit and the rural Bukit Changgang. Employing AiRBOXSense, a rigorously calibrated low-cost sensor in Olak Lempit, alongside data from the Continuous Air Quality Monitoring System (CAQMS) in Bukit Changgang, we provide a comparative analysis of nocturnal versus diurnal air quality. The results reveal higher nocturnal pollutant levels in Olak Lempit, with peak concentrations of 60 ppb for O3, 283.18 ppb for NO2, and 46.16 ppb for CO. In contrast, Bukit Changgang showed lower levels of these pollutants, except for CO and PM2.5. Significantly, CO levels were higher in Bukit Changgang, with values ranging from 349.45 to 805.49 ppb, compared to 156.31 to 344.07 ppb in Olak Lempit. The weak correlation between pollutants and meteorological factors in Olak Lempit indicates local emissions as the primary contributor to increased nocturnal pollutants. This study highlights the distinct patterns of nocturnal air quality in different settings and emphasizes the importance of comprehensive nocturnal air pollution monitoring, reinforced using calibrated sensors, for effective environmental health management.
AB - This study delves into nocturnal air quality, focusing on carbon monoxide (CO), nitrogen dioxide (NO2), surface ozone (O3), and particulate matter (PM2.5), in contrasting areas of Banting, Selangor: the rural-industrial Olak Lempit and the rural Bukit Changgang. Employing AiRBOXSense, a rigorously calibrated low-cost sensor in Olak Lempit, alongside data from the Continuous Air Quality Monitoring System (CAQMS) in Bukit Changgang, we provide a comparative analysis of nocturnal versus diurnal air quality. The results reveal higher nocturnal pollutant levels in Olak Lempit, with peak concentrations of 60 ppb for O3, 283.18 ppb for NO2, and 46.16 ppb for CO. In contrast, Bukit Changgang showed lower levels of these pollutants, except for CO and PM2.5. Significantly, CO levels were higher in Bukit Changgang, with values ranging from 349.45 to 805.49 ppb, compared to 156.31 to 344.07 ppb in Olak Lempit. The weak correlation between pollutants and meteorological factors in Olak Lempit indicates local emissions as the primary contributor to increased nocturnal pollutants. This study highlights the distinct patterns of nocturnal air quality in different settings and emphasizes the importance of comprehensive nocturnal air pollution monitoring, reinforced using calibrated sensors, for effective environmental health management.
KW - Air pollutants
KW - Health risks
KW - Low-cost air quality sensor
UR - http://www.scopus.com/inward/record.url?scp=85188453529&partnerID=8YFLogxK
U2 - 10.1007/s11270-024-07012-9
DO - 10.1007/s11270-024-07012-9
M3 - Article
AN - SCOPUS:85188453529
SN - 0049-6979
VL - 235
JO - Water, Air, & Soil Pollution
JF - Water, Air, & Soil Pollution
IS - 4
M1 - 229
ER -