Abstract
Air gap such as disbond and crack can be successfully detected by ultrasonic testing. But imperfect interface evaluation is still a challenge. The challenge arises from the uncertainty of formation mechanism, boundary condition and acoustical response. In the paper, samples of structure silicon/adhesive/lead-frame, typical in IC packaging, are fabricated with two adesives, degraded through thermo cycling, examined by acoustical waveform and C-imaging, and compared to the measured optical microscopy image and the measured failure shear strength.
Original language | English |
---|---|
Title of host publication | Third International Conference on Experimental Mechanics and Third Conference of the Asian Committee on Experimental Mechanics; Singapore; Singapore; 29 November 2004 through 1 December 2004 |
Pages | 528-533 |
Number of pages | 6 |
Volume | 5852 PART II |
DOIs | |
Publication status | Published - 2005 |
Externally published | Yes |
Event | International Conference on Experimental Mechanics 2004 - Singapore, Singapore Duration: 29 Nov 2004 → 1 Dec 2004 Conference number: 3rd https://www.spiedigitallibrary.org/conference-proceedings-of-spie/5852.toc (Proceedings) |
Publication series
Name | Proceedings of SPIE - The International Society for Optical Engineering |
---|---|
Publisher | SPIE |
ISSN (Print) | 0277-786X |
Conference
Conference | International Conference on Experimental Mechanics 2004 |
---|---|
Abbreviated title | ICEM 2004 |
Country/Territory | Singapore |
City | Singapore |
Period | 29/11/04 → 1/12/04 |
Internet address |
Keywords
- C-scan imaging
- Failure shear strength
- IC packaging
- Quantification of weak bond
- Weak bond