Abstract
The Levenberg-Marquardt parameter identification method is often used in tandem with numerical Runge-Kutta model simulation to find optimal model parameter values to match measured data. However, these methods can potentially find erroneous parameter values. The problem is exacerbated when discontinuous models are analyzed. A highly parameterized respiratory mechanics model defines a pressure-volume response to a low flow experiment in an acute respiratory distress syndrome patient. Levenberg-Marquardt parameter identification is used with various starting values and either a typical numerical integration model simulation or a novel error-stepping method. Model parameter values from the error-stepping method were consistently located close to the error minima (median deviation: 0.4%). In contrast, model values from numerical integration were erratic and distinct from the error minima (median deviation: 1.4%). The comparative failure of Runge-Kutta model simulation was due to the method's poor handling of model discontinuities and the resultant lack of smoothness in the error surface. As the Leven-berg-Marquardt identification system is an error gradient decent method, it depends on accurate measurement of the model-to-measured data error surface. Hence, the method failed to converge accurately due to poorly defined error surfaces. When the error surface is imprecisely identified, the parameter identification process can produce suboptimal results. Particular care must be used when gradient decent methods are used in conjunction with numerical integration model simulation methods and discontinuous models.
Original language | English |
---|---|
Title of host publication | Proceedings of the 8th IFAC Symposium on Biological and Medical Systems, BMS 2012 |
Publisher | Elsevier - International Federation of Automatic Control (IFAC) |
Pages | 490-494 |
Number of pages | 5 |
Edition | 18 |
ISBN (Print) | 9783902823106 |
DOIs | |
Publication status | Published - 2012 |
Externally published | Yes |
Event | IFAC Symposium on Biological and Medical Systems 2012 - Budapest, Hungary Duration: 29 Aug 2012 → 31 Aug 2012 Conference number: 8th https://www.sciencedirect.com/journal/ifac-proceedings-volumes/vol/45/issue/18 (Proceedings) |
Publication series
Name | IFAC Proceedings Volumes (IFAC-PapersOnline) |
---|---|
Number | 18 |
Volume | 45 |
ISSN (Print) | 1474-6670 |
Conference
Conference | IFAC Symposium on Biological and Medical Systems 2012 |
---|---|
Abbreviated title | BMS 2012 |
Country/Territory | Hungary |
City | Budapest |
Period | 29/08/12 → 31/08/12 |
Internet address |
Keywords
- Alveolar recruitment
- Hickling model
- Numerical integration
- Parameter identification
- Physiological modelling