Skip to main navigation Skip to search Skip to main content

Time-dependent in situ measurement of atmospheric corrosion rates of duplex stainless steel wires

  • Cem Örnek
  • , Fabien Léonard
  • , Samuel A. McDonald
  • , Anuj Prajapati
  • , Philip J. Withers
  • , Dirk L. Engelberg

Research output: Contribution to journal › Article › Research › peer-review

Abstract

Corrosion rates of strained grade UNS S32202 (2202) and UNS S32205 (2205) duplex stainless steel wires have been measured, in situ, using time-lapse X-ray computed tomography. Exposures to chloride-containing (MgCl2) atmospheric environments at 50 °C (12–15 M Cl− and pH ~5) with different mechanical elastic and elastic/plastic loads were carried out over a period of 21 months. The corrosion rates for grade 2202 increased over time, showing selective dissolution with shallow corrosion sites, coalescing along the surface of the wire. Corrosion rates of grade 2205 decreased over time, showing both selective and pitting corrosion with more localised attack, growing preferentially in depth. The nucleation of stress corrosion cracking was observed in both wires.

Original languageEnglish
Article number10
Journalnpj Materials Degradation
Volume2
Issue number1
DOIs
Publication statusPublished - Dec 2018
Externally publishedYes

Cite this