The saline infusion test with mass spectrometric measurements of aldosterone to confirm primary aldosteronism

Christina Pamporaki, Hanna Remde, Georgiana Constantinescu, Lydia Kurzinger, Carmina Fuss, Sybille Fuld, Mirko Peitzsch, Manuel Schulze, Francesco Alessi, Myron Lee, Jun Yang, Tracy Ann Williams, Denise Brudgam, Martin Reincke, Sven Gruber, Felix Beuschlein, Jacques W.M. Lenders, Graeme Eisenhofer

Research output: Contribution to journalArticleResearchpeer-review

Abstract

Objective: Confirmation of primary aldosteronism with the saline infusion test requires accurate measurements of plasma aldosterone, which is best achieved by mass spectrometry. Diagnostic performance, appropriate cut-offs and intra-patient variability of the test remain inadequately defined. The objective of this prospective multicenter cohort study was to address these limitations. Methods: Primary aldosteronism was confirmed and excluded using alternative criteria to confirmatory tests in 138 and 282 respective patients with suspected disease. Those criteria were not satisfied in 89 patients. Diagnostic performance of the saline infusion test and optimal cut-offs were determined from receiver operating characteristic curves. Intra-patient variability was determined in 57 patients. Results: Analysis of receiver operating characteristic curves indicated an area under the curve of 0.964 and a cut-off of 169pmol/l for posttest aldosterone concentrations that provided 97% sensitivity and 89% specificity. A cut-off of 255pmol/l enabled improved specificity of 95% at a sensitivity of 75%. Among the 57 patients in whom the saline infusion test was repeated, 15 (26%) had posttest aldosterone concentrations that were discordant using the 169pmol/l cut-off. Eighty percent of the discordant results were from a single center. With exclusion of that center, which did not minimize ambulation during saline infusion, the area under the curve increased to 0.985 and an optimal cutoff of 169pmol/l provided 96% specificity and sensitivity. Conclusion: The seated saline infusion test with mass spectrometric measurements of aldosterone and the cutoffs documented here provides a useful confirmatory test, although this requires adherence to standard-operating procedures. Graphical abstract: http://links.lww.com/COU/A68

Original languageEnglish
Pages (from-to)1666-1674
Number of pages9
JournalJournal of Hypertension
Volume43
Issue number10
DOIs
Publication statusPublished - Oct 2025

Keywords

  • aldosterone
  • confirmatory test
  • diagnosis
  • diagnostic sensitivity
  • diagnostic specificity
  • LC-MS/MS
  • mass spectrometry
  • primary aldosteronism
  • receiver operating characteristic curve
  • saline suppression test