Skip to main navigation Skip to search Skip to main content

The OSCAR-MP Consensus Criteria for Quality Assessment of Retinal Optical Coherence Tomography Angiography

  • Rebecca Wicklein
  • , Charmaine Yam
  • , Christina Noll
  • , Lilian Aly
  • , Nicolas Banze
  • , Eva Feodora Romahn
  • , Elisabeth Wolf
  • , Bernhard Hemmer
  • , Frederike C. Oertel
  • , Hanna Zimmermann
  • , Philipp Albrecht
  • , Marius Ringelstein
  • , Carmen Baumann
  • , Nikolaus Feucht
  • , Josef Penkava
  • , Joachim Havla
  • , Jonathan A. Gernert
  • , Christian Mardin
  • , Eleni S. Vasileiou
  • , Anneke Van Der Walt
  • Omar Al-Louzi, Sergio Cabello, Angela Vidal-Jordana, Julia Krämer, Heinz Wiendl, Jana Lizrova Preiningerova, Olga Ciccarelli, Elena Garcia-Martin, Veronika Kana, Peter A. Calabresi, Friedemann Paul, Shiv Saidha, Axel Petzold, Ahmed T. Toosy, Benjamin Knier, on behalf of IMSVISUAL Consortium

Research output: Contribution to journal › Article › Research › peer-review

Abstract

Background and Objectives Optical coherence tomography angiography (OCTA) is a noninvasive high-resolution imaging technique for assessing the retinal vasculature and is increasingly used in various ophthalmologic, neuro-ophthalmologic, and neurologic diseases. To date, there are no validated consensus criteria for quality control (QC) of OCTA. Our study aimed to develop criteria for OCTA quality assessment. Methods To establish criteria through (1) extensive literature review on OCTA artifacts and image quality to generate standardized and easy-to-apply OCTA QC criteria, (2) application of OCTA QC criteria to evaluate interrater agreement, (3) identification of reasons for interrater disagreement, revision of OCTA QC criteria, development of OCTA QC scoring guide and training set, and (4) validation of QC criteria in an international, interdisciplinary multicenter study. Results We identified 7 major aspects that affect OCTA quality: (O) obvious problems, (S) signal strength, (C) centration, (A) algorithm failure, (R) retinal pathology, (M) motion artifacts, and (P) projection artifacts. Seven independent raters applied the OSCAR-MP criteria to a set of 40 OCTA scans from people with MS, Sjogren syndrome, and uveitis and healthy individuals. The interrater kappa was substantial (κ 0.67). Projection artifacts were the main reason for interrater disagreement. Because artifacts can affect only parts of OCTA images, we agreed that prior definition of a specific region of interest (ROI) is crucial for subsequent OCTA quality assessment. To enhance artifact recognition and interrater agreement on reduced image quality, we designed a scoring guide and OCTA training set. Using these educational tools, 23 raters from 14 different centers reached an almost perfect agreement (κ 0.92) for the rejection of poor-quality OCTA images using the OSCAR-MP criteria. Discussion We propose a 3-step approach for standardized quality control: (1) To define a specific ROI, (2) to assess the occurrence of OCTA artifacts according to the OSCAR-MP criteria, and (3) to evaluate OCTA quality based on the occurrence of different artifacts within the ROI. OSCAR-MP OCTA QC criteria achieved high interrater agreement in an international multicenter study and is a promising QC protocol for application in the context of future clinical trials and studies.

Original languageEnglish
Article numbere200169
Number of pages14
JournalNeurology: Neuroimmunology and NeuroInflammation
Volume10
Issue number6
DOIs
Publication statusPublished - 9 Oct 2023

Cite this