TY - JOUR
T1 - The efficacy of different preprocessing steps in reducing motion-related confounds in diffusion MRI connectomics
AU - Oldham, Stuart
AU - Arnatkeviciute, Aurina
AU - Smith, Robert E.
AU - Tiego, Jeggan
AU - Bellgrove, Mark A.
AU - Fornito, Alex
PY - 2020/11/15
Y1 - 2020/11/15
N2 - Head motion is a major confounding factor in neuroimaging studies. While numerous studies have investigated how motion impacts estimates of functional connectivity, the effects of motion on structural connectivity measured using diffusion MRI have not received the same level of attention, despite the fact that, like functional MRI, diffusion MRI relies on elaborate preprocessing pipelines that require multiple choices at each step. Here, we report a comprehensive analysis of how these choices influence motion-related contamination of structural connectivity estimates. Using a healthy adult sample (N = 294), we evaluated 240 different preprocessing pipelines, devised using plausible combinations of different choices related to explicit head motion correction, tractography propagation algorithms, track seeding methods, track termination constraints, quantitative metrics derived for each connectome edge, and parcellations. We found that an approach to motion correction that includes outlier replacement and within-slice volume correction led to a dramatic reduction in cross-subject correlations between head motion and structural connectivity strength, and that motion contamination is more severe when quantifying connectivity strength using mean tract fractional anisotropy rather than streamline count. We also show that the choice of preprocessing strategy can significantly influence subsequent inferences about network organization, with the location of network hubs varying considerably depending on the specific preprocessing steps applied. Our findings indicate that the impact of motion on structural connectivity can be successfully mitigated using recent motion-correction algorithms that include outlier replacement and within-slice motion correction.
AB - Head motion is a major confounding factor in neuroimaging studies. While numerous studies have investigated how motion impacts estimates of functional connectivity, the effects of motion on structural connectivity measured using diffusion MRI have not received the same level of attention, despite the fact that, like functional MRI, diffusion MRI relies on elaborate preprocessing pipelines that require multiple choices at each step. Here, we report a comprehensive analysis of how these choices influence motion-related contamination of structural connectivity estimates. Using a healthy adult sample (N = 294), we evaluated 240 different preprocessing pipelines, devised using plausible combinations of different choices related to explicit head motion correction, tractography propagation algorithms, track seeding methods, track termination constraints, quantitative metrics derived for each connectome edge, and parcellations. We found that an approach to motion correction that includes outlier replacement and within-slice volume correction led to a dramatic reduction in cross-subject correlations between head motion and structural connectivity strength, and that motion contamination is more severe when quantifying connectivity strength using mean tract fractional anisotropy rather than streamline count. We also show that the choice of preprocessing strategy can significantly influence subsequent inferences about network organization, with the location of network hubs varying considerably depending on the specific preprocessing steps applied. Our findings indicate that the impact of motion on structural connectivity can be successfully mitigated using recent motion-correction algorithms that include outlier replacement and within-slice motion correction.
KW - dMRI
KW - DTI
KW - DWI
KW - FA
KW - Motion
KW - Noise
KW - Structural connectivity
UR - http://www.scopus.com/inward/record.url?scp=85090038255&partnerID=8YFLogxK
U2 - 10.1016/j.neuroimage.2020.117252
DO - 10.1016/j.neuroimage.2020.117252
M3 - Article
C2 - 32800991
AN - SCOPUS:85090038255
SN - 1053-8119
VL - 222
JO - NeuroImage
JF - NeuroImage
M1 - 117252
ER -