Abstract

Typical commercial lease agreements in Australia stipulate 22.5 ± 1.5 °C in summer as the acceptable thermal condition that buildings have to meet, even though the overcooling incurs excessive and unnecessary energy use, gas emissions and financial expense. An argument that backs up this practice asserts that office workers' productivity and comfort will be jeopardised outside this temperature range. This paper investigated whether the office environments with a practical higher temperature setpoint can still be cognitively efficient and comfortable for office workers. In a controlled climate chamber, 26 office workers experienced the typical summer indoor temperature condition in Australia (22 °C) followed by the condition with a higher temperature setpoint (25 °C). In both conditions, subjects were required to fulfil Cambridge Brain Science (CBS) cognitive performance tests, NASA Task Load Index (NASA-TLX), and thermal comfort and air quality questionnaires. Meanwhile, participants' electroencephalogram (EEG) and heart rate (HR) were recorded under three different difficulty levels of Paced Auditory Serial Addition Tests (PASAT). Results showed that CBS test scores were not significantly affected by temperature; a higher temperature of 25 °C incurred a significantly reduced cognitive load for subjects, as has been observed by NASA-TLX, but probably due to the learning effect; the comparison between EEG and HR features during different temperatures did not show any significant difference. Participants' thermal comfort was not significantly jeopardized by the 3 °C temperature setback either. Results from this study favourably support a practical setback of temperature setpoints in Australian office buildings during summer.

Original languageEnglish
Pages (from-to)176-188
Number of pages13
JournalBuilding and Environment
Volume123
DOIs
Publication statusPublished - Oct 2017
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 13 - Climate Action
    SDG 13 Climate Action

Keywords

  • Air-conditioning
  • Cognitive load
  • Higher temperature setpoints
  • Thermal comfort