TY - JOUR
T1 - The diagnostic accuracy of chest ultrasound for CT-detected radiographic consolidation in hospitalised adults with acute respiratory failure
T2 - A systematic review
AU - Hew, Mark
AU - Corcoran, John P.
AU - Harriss, Elinor K.
AU - Rahman, Najib M.
AU - Mallett, Susan
PY - 2015/5/19
Y1 - 2015/5/19
N2 - Objectives: (1) Summarise chest ultrasound accuracy to diagnose radiological consolidation, referenced to chest CT in patients with acute respiratory failure (ARF). (2) Directly compared ultrasound with chest X-ray. Setting: Hospitalised patients. Participants: Studies were eligible if adult participants in respiratory failure underwent chest ultrasound to diagnose consolidation referenced to CT. Exclusion: (1) not primary study, (2) not respiratory failure, (3) not chest ultrasound, (4) not consolidation, (5) translation unobtainable, (6) unable to extract data, (7) unable to obtain paper. 4 studies comprising 224 participants met inclusion. Outcome measures: As planned, paired forest plots display 95% CIs of sensitivity and specificity for ultrasound and chest X-ray. Sensitivity and specificity from each study are plotted in receiver operator characteristics space. Meta-analysis was planned if studies were sufficiently homogeneous and numerous (≥4). Although this numerical requirement was met, meta-analysis was prevented by heterogeneous units of analysis between studies. Results: All studies were in intensive care, with either a high risk of selection bias or high applicability concerns. Studies had unclear or high risk of bias related to use of ultrasound. Only 1 study clearly performed ultrasound within 24 h of respiratory failure diagnosis. Ultrasound sensitivity ranged from 0.91 (95% CI 0.81 to 0.97) to 1.00 (95% CI 0.95 to 1.00). Specificity ranged from 0.78 (95% CI 0.52 to 0.94) to 1.00 (0.99 to 1.00). In two studies, chest X-ray had lower sensitivity than ultrasound, but there were insufficient patients to compare specificity. Conclusions: Four small studies suggest ultrasound is highly sensitive and specific for consolidation in ARF, but high risk of bias and concerns about applicability in all studies may have inflated diagnostic accuracy. Further robustly designed studies are needed to define the role of ultrasound in this setting.
AB - Objectives: (1) Summarise chest ultrasound accuracy to diagnose radiological consolidation, referenced to chest CT in patients with acute respiratory failure (ARF). (2) Directly compared ultrasound with chest X-ray. Setting: Hospitalised patients. Participants: Studies were eligible if adult participants in respiratory failure underwent chest ultrasound to diagnose consolidation referenced to CT. Exclusion: (1) not primary study, (2) not respiratory failure, (3) not chest ultrasound, (4) not consolidation, (5) translation unobtainable, (6) unable to extract data, (7) unable to obtain paper. 4 studies comprising 224 participants met inclusion. Outcome measures: As planned, paired forest plots display 95% CIs of sensitivity and specificity for ultrasound and chest X-ray. Sensitivity and specificity from each study are plotted in receiver operator characteristics space. Meta-analysis was planned if studies were sufficiently homogeneous and numerous (≥4). Although this numerical requirement was met, meta-analysis was prevented by heterogeneous units of analysis between studies. Results: All studies were in intensive care, with either a high risk of selection bias or high applicability concerns. Studies had unclear or high risk of bias related to use of ultrasound. Only 1 study clearly performed ultrasound within 24 h of respiratory failure diagnosis. Ultrasound sensitivity ranged from 0.91 (95% CI 0.81 to 0.97) to 1.00 (95% CI 0.95 to 1.00). Specificity ranged from 0.78 (95% CI 0.52 to 0.94) to 1.00 (0.99 to 1.00). In two studies, chest X-ray had lower sensitivity than ultrasound, but there were insufficient patients to compare specificity. Conclusions: Four small studies suggest ultrasound is highly sensitive and specific for consolidation in ARF, but high risk of bias and concerns about applicability in all studies may have inflated diagnostic accuracy. Further robustly designed studies are needed to define the role of ultrasound in this setting.
UR - http://www.scopus.com/inward/record.url?scp=84930203778&partnerID=8YFLogxK
U2 - 10.1136/bmjopen-2015-007838
DO - 10.1136/bmjopen-2015-007838
M3 - Review Article
AN - SCOPUS:84930203778
SN - 2044-6055
VL - 5
JO - BMJ Open
JF - BMJ Open
IS - 5
M1 - e007838
ER -