Skip to main navigation Skip to search Skip to main content

Synchrotron X-ray diffraction based method for stress intensity factor evaluation in the bulk of materials

Research output: Contribution to journal › Article › Research › peer-review

Abstract

A generalised approach for determining the stress intensity factor in the bulk of non-transparent materials is presented. The new approach combines experimental elastic strain data, measured with powerful synchrotron X-ray diffraction, with an elastic model based on Williams’ series development. The stress intensity factor is calculated using a multi-point over-deterministic method where the number of experimental data points is higher than the number of unknowns describing the elastic field surrounding the crack-tip. The tool is tested on X-ray strain measurements collected on a bainitic steel. In contrast to surface techniques the approach provides insights into the crack tip mechanics deep within the sample and makes full use of the plastic zone data. Satisfactory results are obtained with 1 term in the series development and a smaller region of interest. By increasing the number of terms, it is possible to improve the accuracy in the SIF predictions but this requires a larger region of interest.

Original languageEnglish
Pages (from-to)72-77
Number of pages6
JournalTheoretical and Applied Fracture Mechanics
Volume98
DOIs
Publication statusPublished - Dec 2018
Externally publishedYes

Keywords

  • Bainitic steel
  • Stress intensity factor
  • Williams’ expansion
  • X-ray diffraction

Cite this