Surfactant and physiologic responses of preterm lambs to continuous positive airway pressure

Neil Mulrooney, Zahra Champion, Timothy James Murugesan Moss, Ilias Nitsos, Machiko Ikegami, Alan Jobe

Research output: Contribution to journalArticleResearchpeer-review

Abstract

Although continuous positive airway pressure (CPAP) is used frequently for preterm infants, the relationships between the amount of surfactant and lung physiologic and injury responses to CPAP are unknown. Therefore, saturated phosphatidylcholine (Sat PC) was measured to quantify the surfactant necessary for preterm lambs to breathe successfully on a CPAP of 5 cm H(2)O (CPAP 5). Five of 21 lambs delivered at 130-136 days gestation failed to keep PCO(2) below 100 mm Hg by 2 hours. The lambs that failed had less than 1.9 micromol/kg Sat PC in bronchoalveolar fluid (approximately 3 the pool size at term), less surfactant secretion, and less large aggregate surfactant. Physiologic responses of other 132-day preterm lambs after 2 or 6 hours of CPAP 5, 8 cm H(2)O CPAP (CPAP 8), or mechanical ventilation were then characterized. At 6 hours, oxygenation and lung gas volumes were higher with CPAP 8 relative to the other groups and VE was decreased with CPAP 8 relative to CPAP 5. Lung dry/wet ratios were greater for the CPAP groups than for the mechanical ventilation group. A small amount of endogenous Sat PC is required for preterm lambs to breathe successfully with CPAP. CPAP 8 improves early newborn respiratory transition relative to CPAP 5.
Original languageEnglish
Pages (from-to)488 - 493
Number of pages6
JournalAmerican Journal of Respiratory and Critical Care Medicine
Volume171
Issue number5
DOIs
Publication statusPublished - 2005
Externally publishedYes

Cite this

Mulrooney, Neil ; Champion, Zahra ; Moss, Timothy James Murugesan ; Nitsos, Ilias ; Ikegami, Machiko ; Jobe, Alan. / Surfactant and physiologic responses of preterm lambs to continuous positive airway pressure. In: American Journal of Respiratory and Critical Care Medicine. 2005 ; Vol. 171, No. 5. pp. 488 - 493.
@article{810381bcd36245b4affe9ea22ece8195,
title = "Surfactant and physiologic responses of preterm lambs to continuous positive airway pressure",
abstract = "Although continuous positive airway pressure (CPAP) is used frequently for preterm infants, the relationships between the amount of surfactant and lung physiologic and injury responses to CPAP are unknown. Therefore, saturated phosphatidylcholine (Sat PC) was measured to quantify the surfactant necessary for preterm lambs to breathe successfully on a CPAP of 5 cm H(2)O (CPAP 5). Five of 21 lambs delivered at 130-136 days gestation failed to keep PCO(2) below 100 mm Hg by 2 hours. The lambs that failed had less than 1.9 micromol/kg Sat PC in bronchoalveolar fluid (approximately 3 the pool size at term), less surfactant secretion, and less large aggregate surfactant. Physiologic responses of other 132-day preterm lambs after 2 or 6 hours of CPAP 5, 8 cm H(2)O CPAP (CPAP 8), or mechanical ventilation were then characterized. At 6 hours, oxygenation and lung gas volumes were higher with CPAP 8 relative to the other groups and VE was decreased with CPAP 8 relative to CPAP 5. Lung dry/wet ratios were greater for the CPAP groups than for the mechanical ventilation group. A small amount of endogenous Sat PC is required for preterm lambs to breathe successfully with CPAP. CPAP 8 improves early newborn respiratory transition relative to CPAP 5.",
author = "Neil Mulrooney and Zahra Champion and Moss, {Timothy James Murugesan} and Ilias Nitsos and Machiko Ikegami and Alan Jobe",
year = "2005",
doi = "10.1164/rccm.200406-774OC",
language = "English",
volume = "171",
pages = "488 -- 493",
journal = "American Journal of Respiratory and Critical Care Medicine",
issn = "1073-449X",
publisher = "American Thoracic Society",
number = "5",

}

Surfactant and physiologic responses of preterm lambs to continuous positive airway pressure. / Mulrooney, Neil; Champion, Zahra; Moss, Timothy James Murugesan; Nitsos, Ilias; Ikegami, Machiko; Jobe, Alan.

In: American Journal of Respiratory and Critical Care Medicine, Vol. 171, No. 5, 2005, p. 488 - 493.

Research output: Contribution to journalArticleResearchpeer-review

TY - JOUR

T1 - Surfactant and physiologic responses of preterm lambs to continuous positive airway pressure

AU - Mulrooney, Neil

AU - Champion, Zahra

AU - Moss, Timothy James Murugesan

AU - Nitsos, Ilias

AU - Ikegami, Machiko

AU - Jobe, Alan

PY - 2005

Y1 - 2005

N2 - Although continuous positive airway pressure (CPAP) is used frequently for preterm infants, the relationships between the amount of surfactant and lung physiologic and injury responses to CPAP are unknown. Therefore, saturated phosphatidylcholine (Sat PC) was measured to quantify the surfactant necessary for preterm lambs to breathe successfully on a CPAP of 5 cm H(2)O (CPAP 5). Five of 21 lambs delivered at 130-136 days gestation failed to keep PCO(2) below 100 mm Hg by 2 hours. The lambs that failed had less than 1.9 micromol/kg Sat PC in bronchoalveolar fluid (approximately 3 the pool size at term), less surfactant secretion, and less large aggregate surfactant. Physiologic responses of other 132-day preterm lambs after 2 or 6 hours of CPAP 5, 8 cm H(2)O CPAP (CPAP 8), or mechanical ventilation were then characterized. At 6 hours, oxygenation and lung gas volumes were higher with CPAP 8 relative to the other groups and VE was decreased with CPAP 8 relative to CPAP 5. Lung dry/wet ratios were greater for the CPAP groups than for the mechanical ventilation group. A small amount of endogenous Sat PC is required for preterm lambs to breathe successfully with CPAP. CPAP 8 improves early newborn respiratory transition relative to CPAP 5.

AB - Although continuous positive airway pressure (CPAP) is used frequently for preterm infants, the relationships between the amount of surfactant and lung physiologic and injury responses to CPAP are unknown. Therefore, saturated phosphatidylcholine (Sat PC) was measured to quantify the surfactant necessary for preterm lambs to breathe successfully on a CPAP of 5 cm H(2)O (CPAP 5). Five of 21 lambs delivered at 130-136 days gestation failed to keep PCO(2) below 100 mm Hg by 2 hours. The lambs that failed had less than 1.9 micromol/kg Sat PC in bronchoalveolar fluid (approximately 3 the pool size at term), less surfactant secretion, and less large aggregate surfactant. Physiologic responses of other 132-day preterm lambs after 2 or 6 hours of CPAP 5, 8 cm H(2)O CPAP (CPAP 8), or mechanical ventilation were then characterized. At 6 hours, oxygenation and lung gas volumes were higher with CPAP 8 relative to the other groups and VE was decreased with CPAP 8 relative to CPAP 5. Lung dry/wet ratios were greater for the CPAP groups than for the mechanical ventilation group. A small amount of endogenous Sat PC is required for preterm lambs to breathe successfully with CPAP. CPAP 8 improves early newborn respiratory transition relative to CPAP 5.

UR - http://ajrccm.atsjournals.org/cgi/reprint/171/5/488.pdf

U2 - 10.1164/rccm.200406-774OC

DO - 10.1164/rccm.200406-774OC

M3 - Article

VL - 171

SP - 488

EP - 493

JO - American Journal of Respiratory and Critical Care Medicine

JF - American Journal of Respiratory and Critical Care Medicine

SN - 1073-449X

IS - 5

ER -