Studies on monoxide emission spectrometry of rare earth elements. Part V. Determination of Dy in rare earth concentrates by dual wavelength method

Ying Chen, Jie Zhang, Zaizheng Zhang, Junhua Chen

Research output: Contribution to journalArticleResearchpeer-review

Abstract

The enhancement effect of Pr, Y, Eu and La on the determination of Dy by air-acetylene flame monoxide flame emission spectrometry is reported. The dual wavelength method (526.3 nm as the analytical wavelength and 526.7 nm as the reference wavelength) was used to eliminate spectral interferences. A new method was established for direct determination of Dy (about 4%) in rare-earth mixture concentrates using Pr as enhancing agent and chemical interference inhibitor. The detection limit is 0.4 μg ml-1 Dy and the linear range is 5-900 μg ml-1 Dy.

Original languageEnglish
Pages (from-to)1235-1237
Number of pages3
JournalAnalyst
Volume123
Issue number6
DOIs
Publication statusPublished - 1998
Externally publishedYes

Keywords

  • Dual wavelength method
  • Dysprosium
  • Enhancement effect
  • Monoxide flame emission spectrometry
  • Praseodymium

Cite this