Si nanowires forest-based on-chip biomolecular filtering, separation and preconcentration devices: Nanowires do it all

Vadim Krivitsky, Lo Chang Hsiung, Amir Lichtenstein, Boris Brudnik, Raisa Kantaev, Roey Elnathan, Alexander Pevzner, Artium Khatchtourints, Fernando Patolsky

Research output: Contribution to journalArticleResearchpeer-review

112 Citations (Scopus)

Abstract

The development of efficient biomolecular separation and purification techniques is of critical importance in modern genomics, proteomics, and biosensing areas, primarily due to the fact that most biosamples are mixtures of high diversity and complexity. Most of existent techniques lack the capability to rapidly and selectively separate and concentrate specific target proteins from a complex biosample, and are difficult to integrate with lab-on-a-chip sensing devices. Here, we demonstrate the development of an on-chip all-SiNW filtering, selective separation, desalting, and preconcentration platform for the direct analysis of whole blood and other complex biosamples. The separation of required protein analytes from raw biosamples is first performed using a antibody-modified roughness-controlled SiNWs (silicon nanowires) forest of ultralarge binding surface area, followed by the release of target proteins in a controlled liquid media, and their subsequent detection by supersensitive SiNW-based FETs arrays fabricated on the same chip platform. Importantly, this is the first demonstration of an all-NWs device for the whole direct analysis of blood samples on a single chip, able to selectively collect and separate specific low abundant proteins, while easily removing unwanted blood components (proteins, cells) and achieving desalting effects, without the requirement of time-consuming centrifugation steps, the use of desalting or affinity columns. Futhermore, we have demonstrated the use of our nanowire forest-based separation device, integrated in a single platform with downstream SiNW-based sensors arrays, for the real-time ultrasensitive detection of protein biomarkers directly from blood samples. The whole ultrasensitive protein label-free analysis process can be practically performed in less than 10 min.

Original languageEnglish
Pages (from-to)4748-4756
Number of pages9
JournalNano Letters
Volume12
Issue number9
DOIs
Publication statusPublished - 12 Sept 2012
Externally publishedYes

Keywords

  • biomolecules
  • biosensors
  • filters
  • Nanowire arrays
  • preconcentration
  • separation

Cite this