Short stem shoulder replacement

Research output: Contribution to journalArticleResearchpeer-review

15 Citations (Scopus)

Abstract

Context: It is agreed that it is important to anatomically reproduce the proximal humeral anatomy when performing a prosthetic shoulder replacement. This can be difficult with a long stemmed prosthesis, in particular if there is little relationship of the metaphysis to the humeral shaft. The short stem prosthesis can deal with this problem. Aims: A prospective study assessed the results of total shoulder arthroplasty using a short stem humeral prosthesis, a ceramic humeral head, and a pegged cemented polyethylene glenoid. Materials and methods: Patients with primary shoulder osteoarthritis were recruited into this prospective trial and pre-operatively had the ASES, Constant, SPADI, and DASH scores recorded. The patients were clinically reviewed at the two weeks, eight weeks, one year, and two year mark with completion of a data form. Radiological evaluation was at the eight week, one year and two year follow-up. At the one and two year follow-up the satisfaction rating, the range of passive and active motion, Constant, ASES, SPADI, DASH and pain results were recorded and analysed with SPPS 20. Results: During the study period 97 short stem, ceramic head total shoulder replacements were carried out. At the time of follow-up 12 were two years from operation and 38 one year from operation. Active elevation was overall mean 160 degrees. Constant scores were 76 at 1 year, and 86 at 2 years, ASES 88 and 93, and satisfaction 96 and 98 respectively at one and 2 year follow up. There were no problems during insertion of the humeral prosthesis, or any radiolucent lines or movement of the prosthesis on later radiographs. Conclusion: The short stem prosthesis had no complications, and on follow up radiographs good bone fixation. These fairly short term clinical results were overall good.
Original languageEnglish
Pages (from-to)72 - 75
Number of pages4
JournalInternational Journal of Shoulder Surgery
Volume8
Issue number3
DOIs
Publication statusPublished - 2014

Cite this

@article{32e5f1e0714c4fd3be460a882080c261,
title = "Short stem shoulder replacement",
abstract = "Context: It is agreed that it is important to anatomically reproduce the proximal humeral anatomy when performing a prosthetic shoulder replacement. This can be difficult with a long stemmed prosthesis, in particular if there is little relationship of the metaphysis to the humeral shaft. The short stem prosthesis can deal with this problem. Aims: A prospective study assessed the results of total shoulder arthroplasty using a short stem humeral prosthesis, a ceramic humeral head, and a pegged cemented polyethylene glenoid. Materials and methods: Patients with primary shoulder osteoarthritis were recruited into this prospective trial and pre-operatively had the ASES, Constant, SPADI, and DASH scores recorded. The patients were clinically reviewed at the two weeks, eight weeks, one year, and two year mark with completion of a data form. Radiological evaluation was at the eight week, one year and two year follow-up. At the one and two year follow-up the satisfaction rating, the range of passive and active motion, Constant, ASES, SPADI, DASH and pain results were recorded and analysed with SPPS 20. Results: During the study period 97 short stem, ceramic head total shoulder replacements were carried out. At the time of follow-up 12 were two years from operation and 38 one year from operation. Active elevation was overall mean 160 degrees. Constant scores were 76 at 1 year, and 86 at 2 years, ASES 88 and 93, and satisfaction 96 and 98 respectively at one and 2 year follow up. There were no problems during insertion of the humeral prosthesis, or any radiolucent lines or movement of the prosthesis on later radiographs. Conclusion: The short stem prosthesis had no complications, and on follow up radiographs good bone fixation. These fairly short term clinical results were overall good.",
author = "Bell, {Simon N} and Coghlan, {Jennifer Ann}",
year = "2014",
doi = "10.4103/0973-6042.140113",
language = "English",
volume = "8",
pages = "72 -- 75",
journal = "International Journal of Shoulder Surgery",
issn = "0973-6042",
publisher = "Medknow Publications",
number = "3",

}

Short stem shoulder replacement. / Bell, Simon N; Coghlan, Jennifer Ann.

In: International Journal of Shoulder Surgery, Vol. 8, No. 3, 2014, p. 72 - 75.

Research output: Contribution to journalArticleResearchpeer-review

TY - JOUR

T1 - Short stem shoulder replacement

AU - Bell, Simon N

AU - Coghlan, Jennifer Ann

PY - 2014

Y1 - 2014

N2 - Context: It is agreed that it is important to anatomically reproduce the proximal humeral anatomy when performing a prosthetic shoulder replacement. This can be difficult with a long stemmed prosthesis, in particular if there is little relationship of the metaphysis to the humeral shaft. The short stem prosthesis can deal with this problem. Aims: A prospective study assessed the results of total shoulder arthroplasty using a short stem humeral prosthesis, a ceramic humeral head, and a pegged cemented polyethylene glenoid. Materials and methods: Patients with primary shoulder osteoarthritis were recruited into this prospective trial and pre-operatively had the ASES, Constant, SPADI, and DASH scores recorded. The patients were clinically reviewed at the two weeks, eight weeks, one year, and two year mark with completion of a data form. Radiological evaluation was at the eight week, one year and two year follow-up. At the one and two year follow-up the satisfaction rating, the range of passive and active motion, Constant, ASES, SPADI, DASH and pain results were recorded and analysed with SPPS 20. Results: During the study period 97 short stem, ceramic head total shoulder replacements were carried out. At the time of follow-up 12 were two years from operation and 38 one year from operation. Active elevation was overall mean 160 degrees. Constant scores were 76 at 1 year, and 86 at 2 years, ASES 88 and 93, and satisfaction 96 and 98 respectively at one and 2 year follow up. There were no problems during insertion of the humeral prosthesis, or any radiolucent lines or movement of the prosthesis on later radiographs. Conclusion: The short stem prosthesis had no complications, and on follow up radiographs good bone fixation. These fairly short term clinical results were overall good.

AB - Context: It is agreed that it is important to anatomically reproduce the proximal humeral anatomy when performing a prosthetic shoulder replacement. This can be difficult with a long stemmed prosthesis, in particular if there is little relationship of the metaphysis to the humeral shaft. The short stem prosthesis can deal with this problem. Aims: A prospective study assessed the results of total shoulder arthroplasty using a short stem humeral prosthesis, a ceramic humeral head, and a pegged cemented polyethylene glenoid. Materials and methods: Patients with primary shoulder osteoarthritis were recruited into this prospective trial and pre-operatively had the ASES, Constant, SPADI, and DASH scores recorded. The patients were clinically reviewed at the two weeks, eight weeks, one year, and two year mark with completion of a data form. Radiological evaluation was at the eight week, one year and two year follow-up. At the one and two year follow-up the satisfaction rating, the range of passive and active motion, Constant, ASES, SPADI, DASH and pain results were recorded and analysed with SPPS 20. Results: During the study period 97 short stem, ceramic head total shoulder replacements were carried out. At the time of follow-up 12 were two years from operation and 38 one year from operation. Active elevation was overall mean 160 degrees. Constant scores were 76 at 1 year, and 86 at 2 years, ASES 88 and 93, and satisfaction 96 and 98 respectively at one and 2 year follow up. There were no problems during insertion of the humeral prosthesis, or any radiolucent lines or movement of the prosthesis on later radiographs. Conclusion: The short stem prosthesis had no complications, and on follow up radiographs good bone fixation. These fairly short term clinical results were overall good.

UR - http://search.proquest.com.ezproxy.lib.monash.edu.au/docview/1560657776/fulltextPDF?accountid=12528

U2 - 10.4103/0973-6042.140113

DO - 10.4103/0973-6042.140113

M3 - Article

VL - 8

SP - 72

EP - 75

JO - International Journal of Shoulder Surgery

JF - International Journal of Shoulder Surgery

SN - 0973-6042

IS - 3

ER -