TY - JOUR
T1 - Right ventricular septal pacing
T2 - A comparative study of outflow tract and mid ventricular sites
AU - Rosso, Raphael
AU - Medi, Caroline
AU - Teh, Andrew W.
AU - Hung, Thuy To
AU - Feldman, Alexander
AU - Lee, Geoffrey
AU - Mond, Harry G.
PY - 2010/10/1
Y1 - 2010/10/1
N2 - Background: Prolonged right ventricle (RV) apical pacing is associated with left ventricle (LV) dysfunction due to dysynchronous ventricular activation and contraction. Alternative RV pacing sites with a narrower QRS compared to RV pacing might reflect a more physiological and synchronous LV activation. The purpose of this study was to compare the QRS morphology, duration, and suitability of RV outflow tract (RVOT) septal and mid-RV septal pacing. Methods: Seventeen consecutive patients with indication for dual-chamber pacing were enrolled in the study. Two standard 58-cm active fixation leads were passed to the RV and positioned in the RVOT septum and mid-RV septum using a commercially available septal stylet (model 4140, St. Jude Medical, St. Paul, MN, USA). QRS duration, morphology, and pacing parameters were compared at the two sites. The RV lead with less-satisfactory electrical parameters was withdrawn and deployed in the right atrium. Results: Successful positioning of the pacing leads at the RVOT septum and mid-RV septum was achieved in 15 patients (88.2%). There were no significant differences in the mean stimulation threshold, R-wave sensing, and lead impedance between the two sites. The QRS duration in the RVOT septum was 151 ± 14 ms and in the mid-RV septum 145 ± 13 ms (P = 0.150). Conclusions: This prospective observational study shows that septal pacing can be reliably achieved both in the RVOT and mid-RV with active fixation leads using a specifically shaped stylet. There are no preferences in regard to acute lead performance or paced QRS duration with either position.
AB - Background: Prolonged right ventricle (RV) apical pacing is associated with left ventricle (LV) dysfunction due to dysynchronous ventricular activation and contraction. Alternative RV pacing sites with a narrower QRS compared to RV pacing might reflect a more physiological and synchronous LV activation. The purpose of this study was to compare the QRS morphology, duration, and suitability of RV outflow tract (RVOT) septal and mid-RV septal pacing. Methods: Seventeen consecutive patients with indication for dual-chamber pacing were enrolled in the study. Two standard 58-cm active fixation leads were passed to the RV and positioned in the RVOT septum and mid-RV septum using a commercially available septal stylet (model 4140, St. Jude Medical, St. Paul, MN, USA). QRS duration, morphology, and pacing parameters were compared at the two sites. The RV lead with less-satisfactory electrical parameters was withdrawn and deployed in the right atrium. Results: Successful positioning of the pacing leads at the RVOT septum and mid-RV septum was achieved in 15 patients (88.2%). There were no significant differences in the mean stimulation threshold, R-wave sensing, and lead impedance between the two sites. The QRS duration in the RVOT septum was 151 ± 14 ms and in the mid-RV septum 145 ± 13 ms (P = 0.150). Conclusions: This prospective observational study shows that septal pacing can be reliably achieved both in the RVOT and mid-RV with active fixation leads using a specifically shaped stylet. There are no preferences in regard to acute lead performance or paced QRS duration with either position.
KW - outflow tract and mid ventricular sites
KW - right ventricular septal pacing
UR - http://www.scopus.com/inward/record.url?scp=77957367406&partnerID=8YFLogxK
U2 - 10.1111/j.1540-8159.2010.02836.x
DO - 10.1111/j.1540-8159.2010.02836.x
M3 - Article
C2 - 20636311
AN - SCOPUS:77957367406
SN - 0147-8389
VL - 33
SP - 1169
EP - 1173
JO - Pacing and Clinical Electrophysiology
JF - Pacing and Clinical Electrophysiology
IS - 10
ER -