TY - JOUR
T1 - Revisiting the electrochemical impedance spectroscopy of magnesium with online inductively coupled plasma atomic emission spectroscopy
AU - Shkirskiy, Viacheslav
AU - King, Andrew D
AU - Gharbi, Oumaima
AU - Volovitch, Polina
AU - Scully, John R
AU - Ogle, Kevin
AU - Birbilis, Nick
PY - 2015
Y1 - 2015
N2 - The electrochemical impedance of reactive metals such as magnesium is often complicated by an obvious inductive loop with decreasing frequency of the AC polarising signal. The characterisation and ensuing explanation of this phenomenon has been lacking in the literature to date, being either ignored or speculated. Herein, we couple electrochemical impedance spectroscopy (EIS) with online atomic emission spectroelectrochemistry (AESEC) to simultaneously measure Mg-ion concentration and electrochemical impedance spectra during Mg corrosion, in real time. It is revealed that Mg dissolution occurs via Mg2+, and that corrosion is activated, as measured by AC frequencies less than approximately 1 Hz approaching DC conditions. The result of this is a higher rate of Mg2+ dissolution, as the voltage excitation becomes slow enough to enable all Mg2+-enabling processes to adjust in real time. The manifestation of this in EIS data is an inductive loop. The rationalisation of such EIS behaviour, as it relates to Mg, is revealed for the first time by using concurrent AESEC.
AB - The electrochemical impedance of reactive metals such as magnesium is often complicated by an obvious inductive loop with decreasing frequency of the AC polarising signal. The characterisation and ensuing explanation of this phenomenon has been lacking in the literature to date, being either ignored or speculated. Herein, we couple electrochemical impedance spectroscopy (EIS) with online atomic emission spectroelectrochemistry (AESEC) to simultaneously measure Mg-ion concentration and electrochemical impedance spectra during Mg corrosion, in real time. It is revealed that Mg dissolution occurs via Mg2+, and that corrosion is activated, as measured by AC frequencies less than approximately 1 Hz approaching DC conditions. The result of this is a higher rate of Mg2+ dissolution, as the voltage excitation becomes slow enough to enable all Mg2+-enabling processes to adjust in real time. The manifestation of this in EIS data is an inductive loop. The rationalisation of such EIS behaviour, as it relates to Mg, is revealed for the first time by using concurrent AESEC.
UR - http://onlinelibrary.wiley.com.ezproxy.lib.monash.edu.au/doi/10.1002/cphc.201402666/epdf
U2 - 10.1002/cphc.201402666
DO - 10.1002/cphc.201402666
M3 - Article
SN - 1439-4235
VL - 16
SP - 536
EP - 539
JO - ChemPhysChem
JF - ChemPhysChem
IS - 3
ER -