TY - JOUR
T1 - Resuscitation of patients with durable mechanical circulatory support with acutely altered perfusion or cardiac arrest
T2 - A scoping review
AU - Moskowitz, Ari
AU - Pocock, Helen
AU - Lagina, Anthony
AU - Ng, Kee Chong
AU - Scholefield, Barnaby R.
AU - Zelop, Carolyn M.
AU - Bray, Janet
AU - Rossano, Joseph
AU - Johnson, Nicholas J.
AU - Dunning, Joel
AU - Olasveengen, Theresa
AU - Raymond, Tia
AU - Morales, David L.S.
AU - Carlese, Anthony
AU - Elias, Marie
AU - Berg, Katherine M.
AU - Drennan, Ian
AU - on behalf of the ILCOR Advanced Life Support, Basical Life Support, and Pediatric Life Support Task Forces
N1 - Publisher Copyright:
© 2024 Elsevier B.V.
PY - 2024/10
Y1 - 2024/10
N2 - Background: There is an increasing prevalence of durable mechanical circulatory supported patients in both the in-and-out of hospital communities. The scientific literature regarding the approach to patients supported by durable mechanical circulatory devices who suffer acutely impaired perfusion has not been well explored. Methods: The International Liaison Committee on Resuscitation Advanced, Basic, and Pediatric Life Support Task Forces conducted a scoping review of the literature using a population, context, and concept framework. Results: A total of 32 publications that included patients who were receiving durable mechanical circulatory support and required acute resuscitation were identified. Most of the identified studies were case reports or small case series. Of these, 11 (34.4%) included patients who received chest compressions. A number of studies reported upon delays in the application of chest compressions resulting from complexity due to the expected pulselessness in some patients with continuous flow left-ventricular assist devices as well as from concern regarding potential dislodgement of the mechanical circulatory support device. Three observational studies identified worse outcomes in durable mechanical circulatory support receiving patients with cardiac arrest and acutely impaired perfusion who received chest compressions as compared to those who did not, however those studies were at high risk of bias. Of 226 patients across 11 studies and two published scientific abstracts who sustained cardiac arrest while supported by durable MCS and underwent chest compressions, there were no reported instances of device dislodgement and 71 (31.4%) patients had favorable outcomes. Conclusions: There is a scarcity of evidence to inform the resuscitation of patients with durable mechanical circulatory support (MCS) experiencing acute impairment in perfusion and cardiac arrest. Reports indicate that delays in resuscitation often stem from rescuers’ uncertainty about the safety of administering chest compressions. Notably, no instances of device dislodgement have been documented following chest compressions, suggesting that the risk of harm from timely CPR in these patients is minimal.
AB - Background: There is an increasing prevalence of durable mechanical circulatory supported patients in both the in-and-out of hospital communities. The scientific literature regarding the approach to patients supported by durable mechanical circulatory devices who suffer acutely impaired perfusion has not been well explored. Methods: The International Liaison Committee on Resuscitation Advanced, Basic, and Pediatric Life Support Task Forces conducted a scoping review of the literature using a population, context, and concept framework. Results: A total of 32 publications that included patients who were receiving durable mechanical circulatory support and required acute resuscitation were identified. Most of the identified studies were case reports or small case series. Of these, 11 (34.4%) included patients who received chest compressions. A number of studies reported upon delays in the application of chest compressions resulting from complexity due to the expected pulselessness in some patients with continuous flow left-ventricular assist devices as well as from concern regarding potential dislodgement of the mechanical circulatory support device. Three observational studies identified worse outcomes in durable mechanical circulatory support receiving patients with cardiac arrest and acutely impaired perfusion who received chest compressions as compared to those who did not, however those studies were at high risk of bias. Of 226 patients across 11 studies and two published scientific abstracts who sustained cardiac arrest while supported by durable MCS and underwent chest compressions, there were no reported instances of device dislodgement and 71 (31.4%) patients had favorable outcomes. Conclusions: There is a scarcity of evidence to inform the resuscitation of patients with durable mechanical circulatory support (MCS) experiencing acute impairment in perfusion and cardiac arrest. Reports indicate that delays in resuscitation often stem from rescuers’ uncertainty about the safety of administering chest compressions. Notably, no instances of device dislodgement have been documented following chest compressions, suggesting that the risk of harm from timely CPR in these patients is minimal.
KW - Cardiac Arrest
KW - Left Ventricular Assist Device
KW - Mechanical Circulatory Support
UR - https://www.scopus.com/pages/publications/85204245679
U2 - 10.1016/j.resuscitation.2024.110389
DO - 10.1016/j.resuscitation.2024.110389
M3 - Review Article
C2 - 39245405
AN - SCOPUS:85204245679
SN - 0300-9572
VL - 203
JO - Resuscitation
JF - Resuscitation
M1 - 110389