N2 - Background. Doppler-based renal resistive index (RI) calculation may help in the early detection of acute kidney injury (AKI). Its feasibility and reproducibility by inexperienced operators remain unknown. The main objective of this study was to compare performances of junior and senior operators in assessing renal perfusion using both the semiquantitative color-Doppler scale and RI calculation. Methods. Prospective cohort study performed in 3 ICUs. Inexperienced juniors physicians attended a half-day course on renal perfusion assessment using RI calculation and color-Doppler (from 0, absence of renal perfusion; to 3, renal vessels identifiable in the entire field of view). Junior and senior operators used both methods in 69 mechanically ventilated patients, in blind fashion. Results. Failure to obtain RI occurred for a junior operator in a single patient. RI and color-Doppler semi-quantitative values obtained by operators were correlated (r2=0.64 and r2=0.6l, respectively). Systematic bias across operators as assessed using Bland-Altman plots was negligible (-0.001 and -0.29, respectively), although precision was limited (95% confidence intervals, +0.105 to -0.107 and +0.98 to -1.04, respectively). RI calculation and semi-quantitative assessment performed well for diagnosing persistent AKI (area under the receiver-operating characteristic curve, 0.84 [95% confidence interval, 0.73-0.97] and 0.87 [0.77-0.97], respectively). Conclusion. A brief course on renal Doppler allowed inexperienced operators to assess effectively renal perfusion with a good reliability when compared to senior operators. In addition, our results suggest the good diagnostic performance of both Doppler-based RI and semi-quantitative renal perfusion assessment in predicting short-term renal dysfunction reversibility.
AB - Background. Doppler-based renal resistive index (RI) calculation may help in the early detection of acute kidney injury (AKI). Its feasibility and reproducibility by inexperienced operators remain unknown. The main objective of this study was to compare performances of junior and senior operators in assessing renal perfusion using both the semiquantitative color-Doppler scale and RI calculation. Methods. Prospective cohort study performed in 3 ICUs. Inexperienced juniors physicians attended a half-day course on renal perfusion assessment using RI calculation and color-Doppler (from 0, absence of renal perfusion; to 3, renal vessels identifiable in the entire field of view). Junior and senior operators used both methods in 69 mechanically ventilated patients, in blind fashion. Results. Failure to obtain RI occurred for a junior operator in a single patient. RI and color-Doppler semi-quantitative values obtained by operators were correlated (r2=0.64 and r2=0.6l, respectively). Systematic bias across operators as assessed using Bland-Altman plots was negligible (-0.001 and -0.29, respectively), although precision was limited (95% confidence intervals, +0.105 to -0.107 and +0.98 to -1.04, respectively). RI calculation and semi-quantitative assessment performed well for diagnosing persistent AKI (area under the receiver-operating characteristic curve, 0.84 [95% confidence interval, 0.73-0.97] and 0.87 [0.77-0.97], respectively). Conclusion. A brief course on renal Doppler allowed inexperienced operators to assess effectively renal perfusion with a good reliability when compared to senior operators. In addition, our results suggest the good diagnostic performance of both Doppler-based RI and semi-quantitative renal perfusion assessment in predicting short-term renal dysfunction reversibility.
KW - Acute kidney injury
KW - Critical illness
KW - Doppler
KW - Reproducibility of results
KW - Ultrasonography
UR - http://www.scopus.com/inward/record.url?scp=84924667288&partnerID=8YFLogxK
M3 - Article
C2 - 24569358
AN - SCOPUS:84924667288
SN - 0375-9393
VL - 80
SP - 1273
EP - 1281
JO - Minerva Anestesiologica
JF - Minerva Anestesiologica
IS - 12
ER -