TY - JOUR
T1 - Renal medullary oxygenation during laparoscopic vs open surgery
T2 - the impact of blood pressure management—a pilot randomized controlled trial
AU - Chaba, Anis
AU - Hacking, Doug
AU - Slifirski, Hugh
AU - Cogan, Rebecca
AU - Spano, Sofia
AU - Maeda, Akinori
AU - Eastwood, Glenn
AU - Bellomo, Rinaldo
N1 - Publisher Copyright:
© 2023, The Author(s), under exclusive licence to Springer Nature B.V.
PY - 2024/4
Y1 - 2024/4
N2 - The impact of blood pressure targets and surgical approach (laparoscopic or open) on continuous urinary oxygenation (PuO2), a validated surrogate of renal medullary PO2, during general surgery, is unclear. We aimed to assess the effects of different blood pressure targets and surgical procedures on PuO2. We randomized patients receiving either laparoscopic or open surgery into two mean arterial pressure (MAP) target groups: usual MAP or a high MAP. We measured PuO2 in real-time and analyzed it according to the type of surgery and blood pressure target. The study was retrospectively registered on the 5th of July 2023 (ACTRN12623000726651). We included 43 participants who underwent either laparoscopic (n = 20) or open surgery (n = 23). We found that PuO2 significantly decreased during both laparoscopic and open surgery under a usual blood pressure target (− 51% and − 49%, respectively). However, there was a sharper fall with laparoscopic surgery resulting in a higher PuO2 with open surgery (mean difference: 11 ± 1 mmHg higher; p < 0.001). Targeting a higher MAP resulted in a higher PuO2 over time during laparoscopic surgery (mean difference: 7 ± 1 mmHg, p < 0.001). In contrast, targeting a usual MAP resulted in a higher PuO2 during open surgery (mean difference: 7 ± 1 mmHg, p < 0.001). Surgical approach and intraoperative blood pressure targets significantly impact urinary oxygenation. Further studies with larger sample sizes are needed to confirm these findings and understand their potential clinical implications. Registration number: ACTRN12623000726651; Date of registration: 05/07/2023 (retrospectively registered).
AB - The impact of blood pressure targets and surgical approach (laparoscopic or open) on continuous urinary oxygenation (PuO2), a validated surrogate of renal medullary PO2, during general surgery, is unclear. We aimed to assess the effects of different blood pressure targets and surgical procedures on PuO2. We randomized patients receiving either laparoscopic or open surgery into two mean arterial pressure (MAP) target groups: usual MAP or a high MAP. We measured PuO2 in real-time and analyzed it according to the type of surgery and blood pressure target. The study was retrospectively registered on the 5th of July 2023 (ACTRN12623000726651). We included 43 participants who underwent either laparoscopic (n = 20) or open surgery (n = 23). We found that PuO2 significantly decreased during both laparoscopic and open surgery under a usual blood pressure target (− 51% and − 49%, respectively). However, there was a sharper fall with laparoscopic surgery resulting in a higher PuO2 with open surgery (mean difference: 11 ± 1 mmHg higher; p < 0.001). Targeting a higher MAP resulted in a higher PuO2 over time during laparoscopic surgery (mean difference: 7 ± 1 mmHg, p < 0.001). In contrast, targeting a usual MAP resulted in a higher PuO2 during open surgery (mean difference: 7 ± 1 mmHg, p < 0.001). Surgical approach and intraoperative blood pressure targets significantly impact urinary oxygenation. Further studies with larger sample sizes are needed to confirm these findings and understand their potential clinical implications. Registration number: ACTRN12623000726651; Date of registration: 05/07/2023 (retrospectively registered).
KW - Acute kidney injury
KW - Laparoscopic surgery
KW - Mean arterial pressure
KW - Medullary oxygenation
KW - Open surgery
KW - Urinary oxygenation
UR - http://www.scopus.com/inward/record.url?scp=85174010267&partnerID=8YFLogxK
U2 - 10.1007/s10877-023-01079-1
DO - 10.1007/s10877-023-01079-1
M3 - Article
C2 - 37831377
AN - SCOPUS:85174010267
SN - 1387-1307
VL - 38
SP - 337
EP - 345
JO - Journal of Clinical Monitoring and Computing
JF - Journal of Clinical Monitoring and Computing
IS - 2
ER -