T1 - Relationship of aortic annular eccentricity and paravalvular regurgitation post transcatheter aortic valve implantation with CoreValve
AU - Wong, Dennis TL
AU - Bertaso, Angela
AU - Liew, Gary Y H
AU - Thomson, Viji S
AU - Cunnington, Michael S
AU - Richardson, James D
AU - Gooley, Robert
AU - Lockwood, Siobhan Marie
AU - Meredith, Ian T
AU - Worthley, Matthew I
AU - Worthley, Stephen G
PY - 2013
Y1 - 2013
N2 - Significant paravalvular aortic regurgitation (PAR) after transcatheter aortic valve implantation (TAVI) is associated with negative clinical consequences. We hypothesize that increased eccentricity of the aortic annulus is associated with greater PAR. METHODS: Patients with severe aortic stenosis underwent multidetector computed tomography (MDCT) before successful TAVI with the Medtronic CoreValve bioprosthesis. The smallest (D(min)) and largest (D(max)) orthogonal diameters in the basal ring of the aortic annulus were determined. We defined circularity of aortic annulus using the eccentricity index (1 - D(min)/D(max)). The primary endpoint was early occurrence of significant PAR, defined as > grade II PAR by postprocedural aortography. RESULTS: Eighty-four patients, mean age 83 +/- 4 years with a mean aortic valve area of 0.7 +/- 0.2 cm(2) were included. Twenty patients had postprocedural PAR > grade II. Using a receiver operating characteristic (ROC) analysis, eccentricity index correlated with significant PAR (AUC = 0.834; P=.034). A retrospectively determined eccentricity index cut-off of >0.25 was related to significant PAR with a sensitivity of 80 , specificity of 86 , and negative predictive value of 95 (P0.25 (P0.25 was the sole independent predictor of significant PAR. CONCLUSION: Eccentricity index is related to significant PAR after TAVI with Medtronic CoreValve. Further larger studies are required to determine the utility of this novel index in screening suitable patients for this procedure.
AB - Significant paravalvular aortic regurgitation (PAR) after transcatheter aortic valve implantation (TAVI) is associated with negative clinical consequences. We hypothesize that increased eccentricity of the aortic annulus is associated with greater PAR. METHODS: Patients with severe aortic stenosis underwent multidetector computed tomography (MDCT) before successful TAVI with the Medtronic CoreValve bioprosthesis. The smallest (D(min)) and largest (D(max)) orthogonal diameters in the basal ring of the aortic annulus were determined. We defined circularity of aortic annulus using the eccentricity index (1 - D(min)/D(max)). The primary endpoint was early occurrence of significant PAR, defined as > grade II PAR by postprocedural aortography. RESULTS: Eighty-four patients, mean age 83 +/- 4 years with a mean aortic valve area of 0.7 +/- 0.2 cm(2) were included. Twenty patients had postprocedural PAR > grade II. Using a receiver operating characteristic (ROC) analysis, eccentricity index correlated with significant PAR (AUC = 0.834; P=.034). A retrospectively determined eccentricity index cut-off of >0.25 was related to significant PAR with a sensitivity of 80 , specificity of 86 , and negative predictive value of 95 (P0.25 (P0.25 was the sole independent predictor of significant PAR. CONCLUSION: Eccentricity index is related to significant PAR after TAVI with Medtronic CoreValve. Further larger studies are required to determine the utility of this novel index in screening suitable patients for this procedure.
UR - http://www.invasivecardiology.com/files/190-195%20Wong_April%202013%20wm.pdf
M3 - Article
SN - 1042-3931
VL - 25
SP - 190
EP - 195
JO - Journal of Invasive Cardiology
JF - Journal of Invasive Cardiology
IS - 4
ER -