TY - JOUR
T1 - Recurrent network based power flow solution for voltage stability assessment and improvement with distributed energy sources
AU - Veerasamy, Veerapandiyan
AU - Abdul Wahab, Noor Izzri
AU - Ramachandran, Rajeswari
AU - Othman, Mohammad Lutfi
AU - Hizam, Hashim
AU - Devendran, Vidhya Sagar
AU - Irudayaraj, Andrew Xavier Raj
AU - Vinayagam, Arangarajan
N1 - Funding Information:
The authors gratefully acknowledge the Advanced Lightning and Power Energy System, Universiti Putra Malaysia for providing the research fund under UPM Grant, GPB/2019/9671700 and the facilities to carry out the research. The authors would also like to acknowledge the TEQIP-III-COE-Alternate Energy Research (AER), funded by NPIU, Government College of Technology, Tamil Nadu, India for supporting this research. Also, the authors would like to thank the technical reviewers and editorial member for their comments to improve the quality of the manuscript. The authors further thank the final year students of UPM, Mr. Yu Chai Sek and Mr. Quah Kah Meng for helping us to collect the data during the research project.
Publisher Copyright:
© 2021 Elsevier Ltd
PY - 2021/11/15
Y1 - 2021/11/15
N2 - The increasing penetration of alternative energy sources into the integrated energy systems often influences the voltage stability (VS) of the entire system. However, developing a technique that comprehensively analyze the energy flow in this environment is a major challenge. This paper presents a novel heuristic-based recurrent type Hopfield Neural Network (h-HNN) planning tool for VS assessment of power system; towards reducing the computational cost of conventional power flow (PF) method. The proposed approach is a Jacobian-less, energy function-based approach, which was formulated using power residuals of the system. The dynamics of neural networks were governed by the differential equations of energy function, which would be minimized by the heuristic particle swarm optimization-gravitational search algorithm to deduce the unknown parameters of voltage magnitude and phase angle. The proposed technique was coded in MATLAB and its effectiveness was tested on IEEE 14-, 30-, and 57- buses, as well as a 1354-bus test system. The obtained results were compared with well-known PF techniques, and the robustness was demonstrated for ill-conditioned network. A composite severity index was proposed to rank the critical contingency of the energy network. Then, the VS assessment was performed in IEEE 14-bus system under severe contingency conditions and improvement of VS is observed under the penetration of distributed energy sources (DES). During the case of DES placement, (i) the voltage profile of the system is maintained within the acceptable range of 0.95 to 1.05 pu and (ii) the VS of the system evaluated using stability indices are enhanced by an amount of 16.54 % to 88.16 %. The application results indicate that the proposed method is useful for electric energy utilities to assess the state of the system under monitoring process.
AB - The increasing penetration of alternative energy sources into the integrated energy systems often influences the voltage stability (VS) of the entire system. However, developing a technique that comprehensively analyze the energy flow in this environment is a major challenge. This paper presents a novel heuristic-based recurrent type Hopfield Neural Network (h-HNN) planning tool for VS assessment of power system; towards reducing the computational cost of conventional power flow (PF) method. The proposed approach is a Jacobian-less, energy function-based approach, which was formulated using power residuals of the system. The dynamics of neural networks were governed by the differential equations of energy function, which would be minimized by the heuristic particle swarm optimization-gravitational search algorithm to deduce the unknown parameters of voltage magnitude and phase angle. The proposed technique was coded in MATLAB and its effectiveness was tested on IEEE 14-, 30-, and 57- buses, as well as a 1354-bus test system. The obtained results were compared with well-known PF techniques, and the robustness was demonstrated for ill-conditioned network. A composite severity index was proposed to rank the critical contingency of the energy network. Then, the VS assessment was performed in IEEE 14-bus system under severe contingency conditions and improvement of VS is observed under the penetration of distributed energy sources (DES). During the case of DES placement, (i) the voltage profile of the system is maintained within the acceptable range of 0.95 to 1.05 pu and (ii) the VS of the system evaluated using stability indices are enhanced by an amount of 16.54 % to 88.16 %. The application results indicate that the proposed method is useful for electric energy utilities to assess the state of the system under monitoring process.
KW - Contingency ranking
KW - Distributed energy sources
KW - Heuristic-based Hopfield neural network
KW - Power flow analysis
KW - Voltage stability analysis
UR - https://www.scopus.com/pages/publications/85112307735
U2 - 10.1016/j.apenergy.2021.117524
DO - 10.1016/j.apenergy.2021.117524
M3 - Article
AN - SCOPUS:85112307735
SN - 0306-2619
VL - 302
JO - Applied Energy
JF - Applied Energy
M1 - 117524
ER -