TY - JOUR
T1 - Radiation Dose Associated With Over Scanning in Neck CT
AU - Badawy, Mohamed Khaldoun
AU - Lane, Hannah
AU - Galea, Michael
PY - 2019/7/1
Y1 - 2019/7/1
N2 - The increasing utilization of computed tomography scans exposes patients to significant amounts of radiation. One of the factors that can result in unnecessary radiation dose is scanning beyond the clinically indicated anatomical region. This study aims to assess the optimization in overscan frequency, scan length, and radiation dose following targeted educational talks aimed to address a routinely over scanned protocol; the computed tomography Neck. A targeted radiation awareness talk regarding scan adherence as a method of radiation dose optimization was delivered to all medical imaging technologists employed at a large teaching hospital. An audit of the radiation dose associated with computed tomography Neck protocols was conducted in the month before, a month after and 1 year after the awareness talk. Results show that following the radiation awareness talks there was a 15% reduction in overscan frequency, an average over scan length reduction of 33% and a 20% reduction in overall radiation dose. The targeted nature of the talk, explicitly addressing scan range in the neck region, significantly reduced radiation dose to the patients. The results of this study are effective in illustrating the potential clinical radiation dose saving from strict adherence to scan range.
AB - The increasing utilization of computed tomography scans exposes patients to significant amounts of radiation. One of the factors that can result in unnecessary radiation dose is scanning beyond the clinically indicated anatomical region. This study aims to assess the optimization in overscan frequency, scan length, and radiation dose following targeted educational talks aimed to address a routinely over scanned protocol; the computed tomography Neck. A targeted radiation awareness talk regarding scan adherence as a method of radiation dose optimization was delivered to all medical imaging technologists employed at a large teaching hospital. An audit of the radiation dose associated with computed tomography Neck protocols was conducted in the month before, a month after and 1 year after the awareness talk. Results show that following the radiation awareness talks there was a 15% reduction in overscan frequency, an average over scan length reduction of 33% and a 20% reduction in overall radiation dose. The targeted nature of the talk, explicitly addressing scan range in the neck region, significantly reduced radiation dose to the patients. The results of this study are effective in illustrating the potential clinical radiation dose saving from strict adherence to scan range.
UR - http://www.scopus.com/inward/record.url?scp=85049346829&partnerID=8YFLogxK
U2 - 10.1067/j.cpradiol.2018.05.010
DO - 10.1067/j.cpradiol.2018.05.010
M3 - Article
C2 - 31130179
AN - SCOPUS:85049346829
SN - 0363-0188
VL - 48
SP - 359
EP - 362
JO - Current Problems in Diagnostic Radiology
JF - Current Problems in Diagnostic Radiology
IS - 4
ER -