T1 - Quantitative assessment of the lumbar intervertebral disc via T2 shows excellent long-term reliability
AU - Belavy, Daniel L.
AU - Owen, Patrick J.
AU - Armbrecht, Gabriele
AU - Bansmann, Martin
AU - Zange, Jochen
AU - Ling, Yuan
AU - Pohle-Fröhlich, Regina
AU - Felsenberg, Dieter
N1 - Publisher Copyright:
© 2021 Belavy et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2021/4
Y1 - 2021/4
N2 - Methodologies for the quantitative assessment of the spine tissues, in particular the intervertebral disc (IVD), have not been well established in terms of long-term reliability. This is required for designing prospective studies. 1H water T2 in the IVD ("T2") has attained wider use in assessment of the lumbar intervertebral discs via magnetic resonance imaging. The reliability of IVD T2 measurements are yet to be established. IVD T2 was assessed nine times at regular intervals over 368 days on six anatomical slices centred at the lumbar spine using a spin-echo multi-echo sequence in 12 men. To assess repeatability, intra-class correlation co-efficients (ICCs), standard error of the measurement, minimal detectable difference and co-efficients of variation (CVs) were calculated along with their 95% confidence intervals. Bland-Altman analysis was also performed. ICCs were above 0.93, with the exception of nuclear T2 at L5/S1, where the ICC was 0.88. CVs of the central-slice nucleus sub-region ranged from 4.3% (average of all levels) to 10.1% for L5/S1 and between 2.2% to 3.2% for whole IVD T2 (1.8% for the average of all levels). Averaging between vertebral levels improved reliability. Reliability of measurements was least at L5/S1. ICCs of degenerated IVDs were lower. Test-retest reliability was excellent for whole IVD and good to excellent for IVD subregions. The findings help to establish the long-term repeatability of lumbar IVD T2 for the implementation of prospective studies and determination of significant changes within individuals.
AB - Methodologies for the quantitative assessment of the spine tissues, in particular the intervertebral disc (IVD), have not been well established in terms of long-term reliability. This is required for designing prospective studies. 1H water T2 in the IVD ("T2") has attained wider use in assessment of the lumbar intervertebral discs via magnetic resonance imaging. The reliability of IVD T2 measurements are yet to be established. IVD T2 was assessed nine times at regular intervals over 368 days on six anatomical slices centred at the lumbar spine using a spin-echo multi-echo sequence in 12 men. To assess repeatability, intra-class correlation co-efficients (ICCs), standard error of the measurement, minimal detectable difference and co-efficients of variation (CVs) were calculated along with their 95% confidence intervals. Bland-Altman analysis was also performed. ICCs were above 0.93, with the exception of nuclear T2 at L5/S1, where the ICC was 0.88. CVs of the central-slice nucleus sub-region ranged from 4.3% (average of all levels) to 10.1% for L5/S1 and between 2.2% to 3.2% for whole IVD T2 (1.8% for the average of all levels). Averaging between vertebral levels improved reliability. Reliability of measurements was least at L5/S1. ICCs of degenerated IVDs were lower. Test-retest reliability was excellent for whole IVD and good to excellent for IVD subregions. The findings help to establish the long-term repeatability of lumbar IVD T2 for the implementation of prospective studies and determination of significant changes within individuals.
UR - http://www.scopus.com/inward/record.url?scp=85104102329&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0249855
DO - 10.1371/journal.pone.0249855
M3 - Article
C2 - 33852631
AN - SCOPUS:85104102329
SN - 1932-6203
VL - 16
JO - PLoS ONE
JF - PLoS ONE
IS - 4
M1 - e0249855
ER -