TY - JOUR
T1 - Protein Resistance Driven by Crosslinked Biorecognition Layer for a Win-Win Analysis of the Immunoassay in Urine
AU - Chen, Junhao
AU - Chen, Siyu
AU - Lou, Yafei
AU - Nilghaz, Azadeh
AU - Tian, Junfei
N1 - Publisher Copyright:
© 2025 American Chemical Society.
PY - 2025/6/24
Y1 - 2025/6/24
N2 - Currently, biosensor antifouling and biorecognition layer designs are considered apart. The antifouling layer unavoidably impairs the electrochemical link between the biorecognition layer and base electrodes, resulting in a double-edged antifouling strategy. Here, we propose an approach guided by the concept of the multiplicative sensor, which transforms the biorecognition layer into an antifouling coating. For example, we fabricate a multiplicative sensor integrated with antifouling, hydrogen peroxide detection, and tetramethylbenzidine (TMB) detection in a 2 mm2 working electrode. The antifouling function was obtained by controlling the crosslinking time of bovine serum albumin (BSA) and glucose oxidase (GOx) and remained effective for a week, even in simulations of contamination with plasma and 1 wt % BSA. By leveraging the capacity of the Prussian blue-containing working electrode to detect hydrogen peroxide and TMB and the numerous active functional groups (e.g., −NH3, −COOH) on BSA@GOx, we have successfully constructed both a glucose biosensor and a human chorionic gonadotropin (HCG) immunosensor using the BSA@GOx layer. The multiplicative sensor exhibited detection limits of glucose, and HCG assays were measured as 0.036 mM and 0.341 ng mL-1 with dynamic ranges of 0-0.8 mM and 0.1-100 ng mL-1 (1.24-124 mIU mL-1), respectively. Integrating enzymatic glucose detection into the immunosensor detection process enhances its sensitivity, thereby facilitating the detection of low-concentration enzymatic substrates. We anticipate that this methodology can be easily applied in special electrochemical biosensors featuring simplicity, cost-effectiveness, and high sensitivity.
AB - Currently, biosensor antifouling and biorecognition layer designs are considered apart. The antifouling layer unavoidably impairs the electrochemical link between the biorecognition layer and base electrodes, resulting in a double-edged antifouling strategy. Here, we propose an approach guided by the concept of the multiplicative sensor, which transforms the biorecognition layer into an antifouling coating. For example, we fabricate a multiplicative sensor integrated with antifouling, hydrogen peroxide detection, and tetramethylbenzidine (TMB) detection in a 2 mm2 working electrode. The antifouling function was obtained by controlling the crosslinking time of bovine serum albumin (BSA) and glucose oxidase (GOx) and remained effective for a week, even in simulations of contamination with plasma and 1 wt % BSA. By leveraging the capacity of the Prussian blue-containing working electrode to detect hydrogen peroxide and TMB and the numerous active functional groups (e.g., −NH3, −COOH) on BSA@GOx, we have successfully constructed both a glucose biosensor and a human chorionic gonadotropin (HCG) immunosensor using the BSA@GOx layer. The multiplicative sensor exhibited detection limits of glucose, and HCG assays were measured as 0.036 mM and 0.341 ng mL-1 with dynamic ranges of 0-0.8 mM and 0.1-100 ng mL-1 (1.24-124 mIU mL-1), respectively. Integrating enzymatic glucose detection into the immunosensor detection process enhances its sensitivity, thereby facilitating the detection of low-concentration enzymatic substrates. We anticipate that this methodology can be easily applied in special electrochemical biosensors featuring simplicity, cost-effectiveness, and high sensitivity.
UR - https://www.scopus.com/pages/publications/105007901868
U2 - 10.1021/acs.analchem.5c01393
DO - 10.1021/acs.analchem.5c01393
M3 - Article
AN - SCOPUS:105007901868
SN - 0003-2700
VL - 97
SP - 12699
EP - 12707
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 24
ER -