TY - JOUR
T1 - Predictors of pacemaker requirement in patients receiving implantable loop recorders for unexplained syncope
T2 - A systematic review and meta-analysis
AU - William, Jeremy
AU - Nanayakkara, Shane
AU - Chieng, David
AU - Sugumar, Hariharan
AU - Ling, Liang Han
AU - Patel, Hitesh
AU - Mariani, Justin
AU - Prabhu, Sandeep
AU - Kistler, Peter M.
AU - Voskoboinik, Aleksandr
N1 - Publisher Copyright:
© 2024
PY - 2024/9
Y1 - 2024/9
N2 - Background: Implantable loop recorders (ILRs) are increasingly used to evaluate patients with unexplained syncope. Identification of all predictors of bradycardic syncope and consequent permanent pacemaker (PPM) insertion is of substantial clinical interest as patients in the highest risk category may benefit from upfront pacemaker insertion. Objective: We performed a systematic review and meta-analysis to identify risk predictors for PPM insertion in ILR recipients with unexplained syncope. Methods: An electronic database search (MEDLINE, Embase, Scopus, Cochrane) was performed in June 2023. Studies evaluating ILR recipients with unexplained syncope and recording risk factors for eventual PPM insertion were included. A random effects model was used to calculate the pooled odds ratio (OR) for clinical and electrocardiographic characteristics with respect to future PPM requirement. Results: Eight studies evaluating 1007 ILR recipients were included; 268 patients (26.6%) underwent PPM insertion during study follow-up. PPM recipients were older (mean age, 70.2 ± 15.4 years vs 61.6 ± 19.7 years; P < .001). PR prolongation on baseline electrocardiography was a significant predictor of PPM requirement (pooled OR, 2.91; 95% confidence interval, 1.63–5.20). The presence of distal conduction system disease, encompassing any bundle branch or fascicular block, yielded a pooled OR of 2.88 for PPM insertion (95% confidence interval, 1.53–5.41). Injurious syncope and lack of syncopal prodrome were not significant predictors of PPM insertion. Sinus node dysfunction accounted for 62% of PPM insertions, whereas atrioventricular block accounted for 26%. Conclusion: Approximately one-quarter of ILR recipients for unexplained syncope require eventual PPM insertion. Advancing age, PR prolongation, and distal conduction disease are the strongest predictors for PPM requirement.
AB - Background: Implantable loop recorders (ILRs) are increasingly used to evaluate patients with unexplained syncope. Identification of all predictors of bradycardic syncope and consequent permanent pacemaker (PPM) insertion is of substantial clinical interest as patients in the highest risk category may benefit from upfront pacemaker insertion. Objective: We performed a systematic review and meta-analysis to identify risk predictors for PPM insertion in ILR recipients with unexplained syncope. Methods: An electronic database search (MEDLINE, Embase, Scopus, Cochrane) was performed in June 2023. Studies evaluating ILR recipients with unexplained syncope and recording risk factors for eventual PPM insertion were included. A random effects model was used to calculate the pooled odds ratio (OR) for clinical and electrocardiographic characteristics with respect to future PPM requirement. Results: Eight studies evaluating 1007 ILR recipients were included; 268 patients (26.6%) underwent PPM insertion during study follow-up. PPM recipients were older (mean age, 70.2 ± 15.4 years vs 61.6 ± 19.7 years; P < .001). PR prolongation on baseline electrocardiography was a significant predictor of PPM requirement (pooled OR, 2.91; 95% confidence interval, 1.63–5.20). The presence of distal conduction system disease, encompassing any bundle branch or fascicular block, yielded a pooled OR of 2.88 for PPM insertion (95% confidence interval, 1.53–5.41). Injurious syncope and lack of syncopal prodrome were not significant predictors of PPM insertion. Sinus node dysfunction accounted for 62% of PPM insertions, whereas atrioventricular block accounted for 26%. Conclusion: Approximately one-quarter of ILR recipients for unexplained syncope require eventual PPM insertion. Advancing age, PR prolongation, and distal conduction disease are the strongest predictors for PPM requirement.
KW - Bradycardia
KW - Heart block
KW - Implantable loop recorder
KW - Permanent pacemaker
KW - Sinus node dysfunction
KW - Syncope
UR - http://www.scopus.com/inward/record.url?scp=85191175607&partnerID=8YFLogxK
U2 - 10.1016/j.hrthm.2024.03.038
DO - 10.1016/j.hrthm.2024.03.038
M3 - Article
C2 - 38508296
AN - SCOPUS:85191175607
SN - 1547-5271
VL - 21
SP - 1703
EP - 1710
JO - Heart Rhythm
JF - Heart Rhythm
IS - 9
ER -