TY - JOUR
T1 - Predictors of Failure of Awake Regional Anesthesia for Neonatal Hernia Repair
T2 - Data from the General Anesthesia Compared to Spinal Anesthesia Study-Comparing Apnea and Neurodevelopmental Outcomes
AU - Frawley, Geoff
AU - Bell, Graham
AU - Disma, Nicola
AU - Withington, Davinia E.
AU - De Graaff, Jurgen C.
AU - Morton, Neil S.
AU - McCann, Mary Ellen
AU - Arnup, Sarah J.
AU - Bagshaw, Oliver
AU - Wolfler, Andrea
AU - Bellinger, David
AU - Davidson, Andrew J.
AU - General Anesthesia Compared to Spinal Anesthesia (GAS) Study Consortium
AU - Myles, Paul
AU - Leslie, Kate
PY - 2015/7/20
Y1 - 2015/7/20
N2 - Background: Awake regional anesthesia (RA) is a viable alternative to general anesthesia (GA) for infants undergoing lower abdominal surgery. Benefits include lower incidence of postoperative apnea and avoidance of anesthetic agents that may increase neuroapoptosis and worsen neurocognitive outcomes. The General Anesthesia compared to Spinal anesthesia study compares neurodevelopmental outcomes after awake RA or GA in otherwise healthy infants. The aim of the study is to describe success and failure rates of RA and report factors associated with failure. Methods: This was a nested cohort study within a prospective, randomized, controlled, observer-blind, equivalence trial. Seven hundred twenty-two infants 60 weeks or less postmenstrual age scheduled for herniorrhaphy under anesthesia were randomly assigned to receive RA (spinal, caudal epidural, or combined spinal caudal anesthetic) or GA with sevoflurane. The data of 339 infants, where spinal or combined spinal caudal anesthetic was attempted, were analyzed. Possible predictors of failure were assessed including patient factors, technique, experience of site and anesthetist, and type of local anesthetic. Results: RA was sufficient for the completion of surgery in 83.2% of patients. Spinal anesthesia was successful in 86.9% of cases and combined spinal caudal anesthetic in 76.1%. Thirty-four patients required conversion to GA, and an additional 23 patients (6.8%) required brief sedation. Bloody tap on the first attempt at lumbar puncture was the only risk factor significantly associated with block failure (odds ratio = 2.46). Conclusions: The failure rate of spinal anesthesia was low. Variability in application of combined spinal caudal anesthetic limited attempts to compare the success of this technique to spinal alone.
AB - Background: Awake regional anesthesia (RA) is a viable alternative to general anesthesia (GA) for infants undergoing lower abdominal surgery. Benefits include lower incidence of postoperative apnea and avoidance of anesthetic agents that may increase neuroapoptosis and worsen neurocognitive outcomes. The General Anesthesia compared to Spinal anesthesia study compares neurodevelopmental outcomes after awake RA or GA in otherwise healthy infants. The aim of the study is to describe success and failure rates of RA and report factors associated with failure. Methods: This was a nested cohort study within a prospective, randomized, controlled, observer-blind, equivalence trial. Seven hundred twenty-two infants 60 weeks or less postmenstrual age scheduled for herniorrhaphy under anesthesia were randomly assigned to receive RA (spinal, caudal epidural, or combined spinal caudal anesthetic) or GA with sevoflurane. The data of 339 infants, where spinal or combined spinal caudal anesthetic was attempted, were analyzed. Possible predictors of failure were assessed including patient factors, technique, experience of site and anesthetist, and type of local anesthetic. Results: RA was sufficient for the completion of surgery in 83.2% of patients. Spinal anesthesia was successful in 86.9% of cases and combined spinal caudal anesthetic in 76.1%. Thirty-four patients required conversion to GA, and an additional 23 patients (6.8%) required brief sedation. Bloody tap on the first attempt at lumbar puncture was the only risk factor significantly associated with block failure (odds ratio = 2.46). Conclusions: The failure rate of spinal anesthesia was low. Variability in application of combined spinal caudal anesthetic limited attempts to compare the success of this technique to spinal alone.
UR - https://www.scopus.com/pages/publications/84937484952
U2 - 10.1097/ALN.0000000000000708
DO - 10.1097/ALN.0000000000000708
M3 - Article
C2 - 26001028
AN - SCOPUS:84937484952
SN - 0003-3022
VL - 123
SP - 55
EP - 65
JO - Anesthesiology
JF - Anesthesiology
IS - 1
ER -