TY - JOUR
T1 - Prediction of N95 respirator fit from fogging of eyeglasses
T2 - A pilot study
AU - Kyaw, Sandy
AU - Johns, Moira
AU - Lim, Rimen
AU - Stewart, Warren C.
AU - Rojas, Natalia
AU - Thambiraj, Solomon R.
AU - Shehabi, Yahya
AU - Arora, Sumesh
N1 - Funding Information:
The authors acknowledge the help and advice of Mr. Ricardo Maldonado of Power Stats (West Ryde, New South Wales, Australia. www.powerstats.com.au) in doing the statistics for this study.
Publisher Copyright:
© 2021, Jaypee Brothers Medical Publishers (P) Ltd. All rights reserved.
Copyright:
Copyright 2021 Elsevier B.V., All rights reserved.
PY - 2021/9
Y1 - 2021/9
N2 - Background and objective: Fogging of eyeglasses while wearing N95 respirators is common. It is commonly held that the N95 respirator has a poor fit if there is fogging of eyeglasses. We conducted this prospective, pilot study to determine if fogging of eyeglasses predicts poor fit of N95 respirator. Participants and methods: Seventy volunteer healthcare workers from a tertiary intensive care unit in Sydney, Australia participated. The participants donned one of the following N95 respirators: three-panel flat-fold respirator (3M 1870), cup-shaped respirator (3M 1860), or a duckbill respirator. After a satisfactory “user seal check” as recommended by the manufacturer, the participants donned eyeglasses and checked for fogging. A quantitative fit test (QnFT) of the respirator was then performed (using PortaCount Respirator Fit Tester 8048, TSI Inc., Minnesota, USA). A fit factor of <100 on quantitative fit testing indicates poor fit. The sensitivity and specificity for fogging of eyeglasses (index test) to predict the poor fit of N95 respirator was determined, compared to QnFT (gold standard test). Results: Fogging of eyeglasses as a predictor of poor respirator fit (i.e., fit factor <100 on QnFT) had sensitivity of 71% (95% CI, 54–85%) and specificity 46% (95% CI, 29–63%). The odds ratio of fogging as a predictor for poor fit was 2.10 (95% CI, 0.78–5.67), with a two-tailed p-value of 0.22 (not significant). The receiver operating characteristic curve for fogging of eyeglasses as a diagnostic test had the area under the curve of 0.59. Conclusion: Fogging of eyeglasses is neither a sensitive nor a specific predictor for poor fit of N95 respirators.
AB - Background and objective: Fogging of eyeglasses while wearing N95 respirators is common. It is commonly held that the N95 respirator has a poor fit if there is fogging of eyeglasses. We conducted this prospective, pilot study to determine if fogging of eyeglasses predicts poor fit of N95 respirator. Participants and methods: Seventy volunteer healthcare workers from a tertiary intensive care unit in Sydney, Australia participated. The participants donned one of the following N95 respirators: three-panel flat-fold respirator (3M 1870), cup-shaped respirator (3M 1860), or a duckbill respirator. After a satisfactory “user seal check” as recommended by the manufacturer, the participants donned eyeglasses and checked for fogging. A quantitative fit test (QnFT) of the respirator was then performed (using PortaCount Respirator Fit Tester 8048, TSI Inc., Minnesota, USA). A fit factor of <100 on quantitative fit testing indicates poor fit. The sensitivity and specificity for fogging of eyeglasses (index test) to predict the poor fit of N95 respirator was determined, compared to QnFT (gold standard test). Results: Fogging of eyeglasses as a predictor of poor respirator fit (i.e., fit factor <100 on QnFT) had sensitivity of 71% (95% CI, 54–85%) and specificity 46% (95% CI, 29–63%). The odds ratio of fogging as a predictor for poor fit was 2.10 (95% CI, 0.78–5.67), with a two-tailed p-value of 0.22 (not significant). The receiver operating characteristic curve for fogging of eyeglasses as a diagnostic test had the area under the curve of 0.59. Conclusion: Fogging of eyeglasses is neither a sensitive nor a specific predictor for poor fit of N95 respirators.
KW - Eyeglasses
KW - Healthcare workers
KW - Infectious disease
KW - Intensive care
KW - N95 respirators
KW - Occupational health
UR - http://www.scopus.com/inward/record.url?scp=85114298669&partnerID=8YFLogxK
U2 - 10.5005/jp-journals-10071-23947
DO - 10.5005/jp-journals-10071-23947
M3 - Article
C2 - 34963713
AN - SCOPUS:85114298669
SN - 0972-5229
VL - 25
SP - 976
EP - 980
JO - Indian Journal of Critical Care Medicine
JF - Indian Journal of Critical Care Medicine
IS - 9
ER -