The use of wide, post-tensioned band beams for floor systems is extremely common in Australia. They are required to be capable of deforming with a building during an earthquake, and are increasingly being used as part of the lateral resistance of a building. However, relatively little is known about their performance under earthquake loading. This paper presents the results achieved for a post-tensioned wide band beam subject to lateral loads, designed and detailed to resist gravity loading, and the reparation and re-testing using CFRP. The results achieved have shown that both this type of construction and this type of repair are capable of achieving sufficient drift ratios without significant loss in capacity for areas of low to moderate seismicity. There is also potential for use in areas of higher seismicity.

Original languageEnglish
Title of host publicationProceedings of the 4th Asia-Pacific Conference on FRP in Structures (APFIS 2013)
Subtitle of host publicationMelbourne Vic Australia; 11-13 December 2013
EditorsRiadh Al-Mahaidi, Scott T. Smith, Yu Bai, Xiao-Ling Zhao
Place of PublicationMelbourne Vic Australia
PublisherInternational Institute for FRP in Construction (IIFC)
Pages1-7
Number of pages7
ISBN (Electronic)9780987593016
Publication statusPublished - 2013
Externally publishedYes
EventAsia-Pacific Conference on FRP in Structures 2013 - Melbourne, Australia
Duration: 11 Dec 201313 Dec 2013
Conference number: 4th

Conference

ConferenceAsia-Pacific Conference on FRP in Structures 2013
Abbreviated titleAPFIS 2013
Country/TerritoryAustralia
CityMelbourne
Period11/12/1313/12/13

Keywords

  • CFRP
  • Post-tensioned concrete
  • Repair
  • Seismic
  • Wide beam

Cite this