TY - JOUR
T1 - Peering further into the mind’s eye
T2 - combining visual evoked potential and optical coherence tomography measures enhances insight into the variance in cognitive functioning in multiple sclerosis
AU - Covey, Thomas J.
AU - Golan, Daniel
AU - Sergott, Robert
AU - Wilken, Jeffrey
AU - Zarif, Myassar
AU - Bumstead, Barbara
AU - Buhse, Mari Jean
AU - Kaczmarek, Olivia
AU - Doniger, Glen M.
AU - Penner, Iris Katharina
AU - Hancock, Laura M.
AU - Bogaardt, Hans
AU - Barrera, Marissa A.
AU - Morrow, Sarah A.
AU - Galetta, Steve
AU - Gudesblatt, Mark
N1 - Publisher Copyright:
© 2023, The Author(s), under exclusive licence to Springer-Verlag GmbH Germany.
PY - 2024/2
Y1 - 2024/2
N2 - Background: Spectral Optical Coherence Tomography (OCT) and Visual Evoked Potentials (VEPs) have both emerged as potentially useful biomarkers of cognitive decline in people with multiple sclerosis (PwMS). Their combined use may provide additional predictive value for identifying disease impact, progression, and remyelination capacity above-and-beyond what is captured using either approach alone. Objective: We examined the relationship between OCT/VEP measures and cognitive functioning in 205 PwMS. OCT measures included Retinal Nerve Fiber Layer Volume (RNFLV), Papillo-Macular Bundle Volume (PBMV), and Macular Volume (MV). VEP measures included latency of the P100, and inter-ocular latency. Cognitive performance was evaluated across seven separate domains of performance, and for overall cognition, using the NeuroTrax computerized testing battery. Results: Both OCT and VEP measures were significantly correlated with cognitive performance across several domains. Linear regression models that controlled for the influence of visual acuity revealed (1) that reduced MV was significantly predictive of poorer visual-spatial functioning, and (2) that delayed VEP latency was significantly predictive of performance in global cognitive functioning and visual-spatial functioning, after controlling for multiple comparisons. Among PwMS with normal visual acuity, PwMS with a combination of both relatively low MV and delayed VEP latency tended to have poorer performance in the domains of global, executive, and visual-spatial functioning compared to PwMS with both high MV and normal VEP latency. Conclusion: Approaches that combine the use of OCT and VEP measures can enhance insight into underlying factors that contribute to variance in cognitive functioning in PwMS.
AB - Background: Spectral Optical Coherence Tomography (OCT) and Visual Evoked Potentials (VEPs) have both emerged as potentially useful biomarkers of cognitive decline in people with multiple sclerosis (PwMS). Their combined use may provide additional predictive value for identifying disease impact, progression, and remyelination capacity above-and-beyond what is captured using either approach alone. Objective: We examined the relationship between OCT/VEP measures and cognitive functioning in 205 PwMS. OCT measures included Retinal Nerve Fiber Layer Volume (RNFLV), Papillo-Macular Bundle Volume (PBMV), and Macular Volume (MV). VEP measures included latency of the P100, and inter-ocular latency. Cognitive performance was evaluated across seven separate domains of performance, and for overall cognition, using the NeuroTrax computerized testing battery. Results: Both OCT and VEP measures were significantly correlated with cognitive performance across several domains. Linear regression models that controlled for the influence of visual acuity revealed (1) that reduced MV was significantly predictive of poorer visual-spatial functioning, and (2) that delayed VEP latency was significantly predictive of performance in global cognitive functioning and visual-spatial functioning, after controlling for multiple comparisons. Among PwMS with normal visual acuity, PwMS with a combination of both relatively low MV and delayed VEP latency tended to have poorer performance in the domains of global, executive, and visual-spatial functioning compared to PwMS with both high MV and normal VEP latency. Conclusion: Approaches that combine the use of OCT and VEP measures can enhance insight into underlying factors that contribute to variance in cognitive functioning in PwMS.
KW - Cognitive functioning
KW - Macular volume
KW - Occipital coherence tomography
KW - P100
KW - Visual evoked potentials
UR - https://www.scopus.com/pages/publications/85179694143
U2 - 10.1007/s00415-023-12075-5
DO - 10.1007/s00415-023-12075-5
M3 - Article
C2 - 38091086
AN - SCOPUS:85179694143
SN - 0340-5354
VL - 271
SP - 658
EP - 673
JO - Journal of Neurology
JF - Journal of Neurology
IS - 2
ER -