TY - JOUR
T1 - Osteoarthritis is associated with increased failure of proximal femoral fracture fixation
AU - Gallagher, Charles A.
AU - Jones, Christopher W.
AU - Kimmel, Lara
AU - Wylde, Christopher
AU - Osbrough, Anthony
AU - Bulsara, Max
AU - Hird, Kathryn
AU - Yates, Piers
PY - 2019/5
Y1 - 2019/5
N2 - Purpose: The purpose of this study was to evaluate whether the presence of hip osteoarthritis at the time of hip fracture increases treatment failure rates when using either a sliding hip screw (SHS) or proximal femoral nail (PFN) for fracture fixation. Methods: A retrospective study of a consecutive series of 455 women and 148 men (median age, 83.8 years) treated with SHS or PFN was performed. Osteoarthritis was evaluated based on pre-operative radiographs using the Kellgren and Lawrence grading system. Treatment failure, which was defined as non-union, avascular necrosis, backing out of the implant, cut out of the proximal screws, peri-prosthetic fracture, implant breakage, or conversion to hemi- or total hip arthroplasty, was evaluated for a follow-up period of four to seven years. Optimal placement of the implant (tip-apex distance (TAD) and 3-point fixation) and the effects of age, sex, the quality of reduction, implant type, fracture stability, fracture type, and time to failure were considered confounders of the relationship between failure and osteoarthritis (OA). Results: Among the 32 cases (5.3%) of treatment failure, 12 (2%) showed evidence of osteoarthritis. After controlling for age, sex, the quality of reduction, implant type, fracture stability, fracture type, and TAD, osteoarthritis was associated a greater than threefold increase in treatment failure compared with that of patients without pre-operative evidence of osteoarthritis (OR, 3.26; 95% CI, 1.4–7.65; P = 0.006). Conclusions: After adjusting for potential confounding factors, radiographic evidence of hip osteoarthritis at the time of hip fracture increases the incidence of treatment failure.
AB - Purpose: The purpose of this study was to evaluate whether the presence of hip osteoarthritis at the time of hip fracture increases treatment failure rates when using either a sliding hip screw (SHS) or proximal femoral nail (PFN) for fracture fixation. Methods: A retrospective study of a consecutive series of 455 women and 148 men (median age, 83.8 years) treated with SHS or PFN was performed. Osteoarthritis was evaluated based on pre-operative radiographs using the Kellgren and Lawrence grading system. Treatment failure, which was defined as non-union, avascular necrosis, backing out of the implant, cut out of the proximal screws, peri-prosthetic fracture, implant breakage, or conversion to hemi- or total hip arthroplasty, was evaluated for a follow-up period of four to seven years. Optimal placement of the implant (tip-apex distance (TAD) and 3-point fixation) and the effects of age, sex, the quality of reduction, implant type, fracture stability, fracture type, and time to failure were considered confounders of the relationship between failure and osteoarthritis (OA). Results: Among the 32 cases (5.3%) of treatment failure, 12 (2%) showed evidence of osteoarthritis. After controlling for age, sex, the quality of reduction, implant type, fracture stability, fracture type, and TAD, osteoarthritis was associated a greater than threefold increase in treatment failure compared with that of patients without pre-operative evidence of osteoarthritis (OR, 3.26; 95% CI, 1.4–7.65; P = 0.006). Conclusions: After adjusting for potential confounding factors, radiographic evidence of hip osteoarthritis at the time of hip fracture increases the incidence of treatment failure.
KW - Failure
KW - Fracture
KW - Hip
KW - Neck of femur
KW - Osteoarthritis
KW - Treatment
UR - http://www.scopus.com/inward/record.url?scp=85048776819&partnerID=8YFLogxK
U2 - 10.1007/s00264-018-4014-8
DO - 10.1007/s00264-018-4014-8
M3 - Article
AN - SCOPUS:85048776819
SN - 0341-2695
VL - 43
SP - 1223
EP - 1230
JO - International Orthopaedics
JF - International Orthopaedics
IS - 5
ER -