Neural electrodes used for in vivo biomedical applications (e.g., prostheses, bionic implants) result in glial invasion, leading to the formation of a nonexcitable scar that increases the distance between neurons and electrode and increases the resistance to current flow. The result is progressive deterioration in the performance of stimulation or recording of neural activity and inevitable device failure. Also, electrodes with a 2D surface have a limited proximity to neurons. In the present study, a macroporous and fibrous 3D neural electrode is developed using poly-L-lactic acid fibrous membranes imbued with electroactive properties via a coating of the conductive polymer poly(3,4-ethylenedioxythiophene) (PEDOT), using vapor phase polymerization. The electrical properties of the PEDOT-coated substrates are studied using sheet resistance and impedance. PEDOT electrode biocompatibility is assessed through in vitro assays using patch-clamp electrophysiology and calcium imaging of isolated and cultured rat hippocampal neurons. PEDOT fibers support robust normal functional development of neurons, including synaptic networking and communication. Stimulation and recording of activity in brain slices and from the surface of the brain using 3D-PEDOT fibrous electrodes are indistinguishable from recordings using conventional glass or platinum electrodes. In vivo studies reveal minimal reactive gliosis in response to electrode implantation.

Original languageEnglish
Article number1700927
Number of pages12
JournalAdvanced Functional Materials
Volume28
Issue number12
DOIs
Publication statusPublished - 21 Mar 2018

Keywords

  • electrophysiology
  • neural electrodes
  • neural interfaces
  • poly(3,4-ethylenedioxythiophene) (PEDOT)

Cite this

Marroquin, Jason B. ; Coleman, Harold A. ; Tonta, Mary A. ; Zhou, Kun ; Winther-Jensen, Bjorn ; Fallon, James ; Duffy, Noel W. ; Yan, Edwin ; Abdulwahid, Ammar A. ; Jasieniak, Jacek J. ; Forsythe, John S. ; Parkington, Helena C. / Neural Electrodes Based on 3D Organic Electroactive Microfibers. In: Advanced Functional Materials. 2018 ; Vol. 28, No. 12.
@article{704db0ead1474c61a200fd995c625933,
title = "Neural Electrodes Based on 3D Organic Electroactive Microfibers",
abstract = "Neural electrodes used for in vivo biomedical applications (e.g., prostheses, bionic implants) result in glial invasion, leading to the formation of a nonexcitable scar that increases the distance between neurons and electrode and increases the resistance to current flow. The result is progressive deterioration in the performance of stimulation or recording of neural activity and inevitable device failure. Also, electrodes with a 2D surface have a limited proximity to neurons. In the present study, a macroporous and fibrous 3D neural electrode is developed using poly-L-lactic acid fibrous membranes imbued with electroactive properties via a coating of the conductive polymer poly(3,4-ethylenedioxythiophene) (PEDOT), using vapor phase polymerization. The electrical properties of the PEDOT-coated substrates are studied using sheet resistance and impedance. PEDOT electrode biocompatibility is assessed through in vitro assays using patch-clamp electrophysiology and calcium imaging of isolated and cultured rat hippocampal neurons. PEDOT fibers support robust normal functional development of neurons, including synaptic networking and communication. Stimulation and recording of activity in brain slices and from the surface of the brain using 3D-PEDOT fibrous electrodes are indistinguishable from recordings using conventional glass or platinum electrodes. In vivo studies reveal minimal reactive gliosis in response to electrode implantation.",
keywords = "electrophysiology, neural electrodes, neural interfaces, poly(3,4-ethylenedioxythiophene) (PEDOT)",
author = "Marroquin, {Jason B.} and Coleman, {Harold A.} and Tonta, {Mary A.} and Kun Zhou and Bjorn Winther-Jensen and James Fallon and Duffy, {Noel W.} and Edwin Yan and Abdulwahid, {Ammar A.} and Jasieniak, {Jacek J.} and Forsythe, {John S.} and Parkington, {Helena C.}",
year = "2018",
month = "3",
day = "21",
doi = "10.1002/adfm.201700927",
language = "English",
volume = "28",
journal = "Advanced Functional Materials",
issn = "1616-301X",
publisher = "Wiley-VCH Verlag GmbH & Co. KGaA",
number = "12",

}

Neural Electrodes Based on 3D Organic Electroactive Microfibers. / Marroquin, Jason B.; Coleman, Harold A.; Tonta, Mary A.; Zhou, Kun; Winther-Jensen, Bjorn; Fallon, James; Duffy, Noel W.; Yan, Edwin; Abdulwahid, Ammar A.; Jasieniak, Jacek J.; Forsythe, John S.; Parkington, Helena C.

In: Advanced Functional Materials, Vol. 28, No. 12, 1700927, 21.03.2018.

Research output: Contribution to journalArticleResearchpeer-review

TY - JOUR

T1 - Neural Electrodes Based on 3D Organic Electroactive Microfibers

AU - Marroquin, Jason B.

AU - Coleman, Harold A.

AU - Tonta, Mary A.

AU - Zhou, Kun

AU - Winther-Jensen, Bjorn

AU - Fallon, James

AU - Duffy, Noel W.

AU - Yan, Edwin

AU - Abdulwahid, Ammar A.

AU - Jasieniak, Jacek J.

AU - Forsythe, John S.

AU - Parkington, Helena C.

PY - 2018/3/21

Y1 - 2018/3/21

N2 - Neural electrodes used for in vivo biomedical applications (e.g., prostheses, bionic implants) result in glial invasion, leading to the formation of a nonexcitable scar that increases the distance between neurons and electrode and increases the resistance to current flow. The result is progressive deterioration in the performance of stimulation or recording of neural activity and inevitable device failure. Also, electrodes with a 2D surface have a limited proximity to neurons. In the present study, a macroporous and fibrous 3D neural electrode is developed using poly-L-lactic acid fibrous membranes imbued with electroactive properties via a coating of the conductive polymer poly(3,4-ethylenedioxythiophene) (PEDOT), using vapor phase polymerization. The electrical properties of the PEDOT-coated substrates are studied using sheet resistance and impedance. PEDOT electrode biocompatibility is assessed through in vitro assays using patch-clamp electrophysiology and calcium imaging of isolated and cultured rat hippocampal neurons. PEDOT fibers support robust normal functional development of neurons, including synaptic networking and communication. Stimulation and recording of activity in brain slices and from the surface of the brain using 3D-PEDOT fibrous electrodes are indistinguishable from recordings using conventional glass or platinum electrodes. In vivo studies reveal minimal reactive gliosis in response to electrode implantation.

AB - Neural electrodes used for in vivo biomedical applications (e.g., prostheses, bionic implants) result in glial invasion, leading to the formation of a nonexcitable scar that increases the distance between neurons and electrode and increases the resistance to current flow. The result is progressive deterioration in the performance of stimulation or recording of neural activity and inevitable device failure. Also, electrodes with a 2D surface have a limited proximity to neurons. In the present study, a macroporous and fibrous 3D neural electrode is developed using poly-L-lactic acid fibrous membranes imbued with electroactive properties via a coating of the conductive polymer poly(3,4-ethylenedioxythiophene) (PEDOT), using vapor phase polymerization. The electrical properties of the PEDOT-coated substrates are studied using sheet resistance and impedance. PEDOT electrode biocompatibility is assessed through in vitro assays using patch-clamp electrophysiology and calcium imaging of isolated and cultured rat hippocampal neurons. PEDOT fibers support robust normal functional development of neurons, including synaptic networking and communication. Stimulation and recording of activity in brain slices and from the surface of the brain using 3D-PEDOT fibrous electrodes are indistinguishable from recordings using conventional glass or platinum electrodes. In vivo studies reveal minimal reactive gliosis in response to electrode implantation.

KW - electrophysiology

KW - neural electrodes

KW - neural interfaces

KW - poly(3,4-ethylenedioxythiophene) (PEDOT)

UR - http://www.scopus.com/inward/record.url?scp=85044391060&partnerID=8YFLogxK

U2 - 10.1002/adfm.201700927

DO - 10.1002/adfm.201700927

M3 - Article

VL - 28

JO - Advanced Functional Materials

JF - Advanced Functional Materials

SN - 1616-301X

IS - 12

M1 - 1700927

ER -

Marroquin JB, Coleman HA, Tonta MA, Zhou K, Winther-Jensen B, Fallon J et al. Neural Electrodes Based on 3D Organic Electroactive Microfibers. Advanced Functional Materials. 2018 Mar 21;28(12). 1700927. https://doi.org/10.1002/adfm.201700927