TY - JOUR
T1 - Myocardial Function during Ventilation with Lower versus Higher Positive End-Expiratory Pressure in Patients without ARDS
AU - Algera, Anna Geke
AU - Pierrakos, Charalampos
AU - Botta, Michela
AU - Zimatore, Claudio
AU - Pisani, Luigi
AU - Tuinman, Pieter Roel
AU - Bos, Lieuwe D.J.
AU - Lagrand, Wim K.
AU - de Abreu, Marcello Gama
AU - Pelosi, Paolo
AU - Neto, Ary Serpa
AU - Schultz, Marcus J.
AU - Cherpanath, Thomas G.V.
AU - Paulus, Frederique
N1 - Funding Information:
This study was supported by a grant from ZonMW (the Netherlands Organization for Health Research and Development) and the Amsterdam University Medical Centers, Location AMC. The funding sources had no role in the design and conduct of the study; collection, management, analysis, and interpretation of the data; preparation, review, or approval of the manuscript; or decision to submit the manuscript for publication.
Publisher Copyright:
© 2022 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2022/5/1
Y1 - 2022/5/1
N2 - The aim of this study was to investigate whether lower PEEP (positive end-expiratory pressure) had beneficial effects on myocardial function among intensive care unit (ICU) patients without acute respiratory distress syndrome (ARDS) compared to higher PEEP. In this pre-planned substudy of a randomized controlled trial (RELAx), comparing lower to higher PEEP, 44 patients underwent transthoracic echocardiography. The exclusion criteria were known poor left ventricular function and severe shock requiring high dosages of norepinephrine. To create contrast, we also excluded patients who received PEEP between 2 cmH2O and 7 cmH2O in the two randomization arms of the study. The primary outcome was the right ventricular myocardial performance index (MPI), a measure of systolic and diastolic function. The secondary outcomes included systolic and diastolic function parameters. A total of 20 patients were ventilated with lower PEEP (mean ± SD, 0 ± 1 cmH2O), and 24 patients, with higher PEEP (8 ± 1 cmH2O) (mean difference, −8 cmH2O; 95% CI: −8.1 to −7.9 cmH2O; p = 0.01). The tidal volume size was low in both groups (median (IQR), 7.2 (6.3 to 8.1) versus 7.0 (5.3 to 9.1) ml/kg PBW; p = 0.97). The median right ventricular MPI was 0.32 (IQR, 0.26 to 0.39) in the lower-PEEP group versus 0.38 (0.32 to 0.41) in the higher-PEEP group; the median difference was –0.03; 95% CI: −0.11 to 0.03; p = 0.33. The other systolic and diastolic parameters were similar. In patients without ARDS ventilated with a low tidal volume, a lower PEEP had no beneficial effects on the right ventricular MPI.
AB - The aim of this study was to investigate whether lower PEEP (positive end-expiratory pressure) had beneficial effects on myocardial function among intensive care unit (ICU) patients without acute respiratory distress syndrome (ARDS) compared to higher PEEP. In this pre-planned substudy of a randomized controlled trial (RELAx), comparing lower to higher PEEP, 44 patients underwent transthoracic echocardiography. The exclusion criteria were known poor left ventricular function and severe shock requiring high dosages of norepinephrine. To create contrast, we also excluded patients who received PEEP between 2 cmH2O and 7 cmH2O in the two randomization arms of the study. The primary outcome was the right ventricular myocardial performance index (MPI), a measure of systolic and diastolic function. The secondary outcomes included systolic and diastolic function parameters. A total of 20 patients were ventilated with lower PEEP (mean ± SD, 0 ± 1 cmH2O), and 24 patients, with higher PEEP (8 ± 1 cmH2O) (mean difference, −8 cmH2O; 95% CI: −8.1 to −7.9 cmH2O; p = 0.01). The tidal volume size was low in both groups (median (IQR), 7.2 (6.3 to 8.1) versus 7.0 (5.3 to 9.1) ml/kg PBW; p = 0.97). The median right ventricular MPI was 0.32 (IQR, 0.26 to 0.39) in the lower-PEEP group versus 0.38 (0.32 to 0.41) in the higher-PEEP group; the median difference was –0.03; 95% CI: −0.11 to 0.03; p = 0.33. The other systolic and diastolic parameters were similar. In patients without ARDS ventilated with a low tidal volume, a lower PEEP had no beneficial effects on the right ventricular MPI.
KW - ARDS
KW - ICU
KW - mechanical ventilation
KW - MPI
KW - myocardial function
KW - PEEP
UR - http://www.scopus.com/inward/record.url?scp=85128567053&partnerID=8YFLogxK
U2 - 10.3390/jcm11092309
DO - 10.3390/jcm11092309
M3 - Article
C2 - 35566435
AN - SCOPUS:85128567053
SN - 2077-0383
VL - 11
JO - Journal of Clinical Medicine
JF - Journal of Clinical Medicine
IS - 9
M1 - 2309
ER -