Miniaturisation and simplification of solid-state proton activity sensors for non-aqueous media and ionic liquids

Orawan Winther-Jensen, Jessie L. Hamilton, Chun H. Ng, Bartlomiej Kolodziejczyk, Bjorn Winther-Jensen

Research output: Contribution to journalArticleResearchpeer-review

Abstract

This work is the further development of the previous pH (effective) sensor work where a biologically derived proton-active redox centre – riboflavin (RFN) – was entrapped into a vapour phase polymerised poly(3,4- ethylenedioxythiophene) film and ferrocene (Fc) dissolved in the sample solution was used as an internal reference redox couple. Here, we report a disposable solid state pH (effective) sensor where we successfully incorporated both RFN and Fc into a single solid state electrode. The electrodes were then used for pH (effective) sensing where water is not required. The system was further miniaturised and simplified from a 3 electrode to a 2 electrode setup with the working electrode area being as small as 0.09 mm2. The sensors show the ability to measure pH (effective) in both aqueous and non-aqueous media including ionic liquids (ILs) regardless of their hydrophobicity. This is an important step towards the ability to customise ILs or non-aqueous media with suitable proton activity (PA) for various applications e.g. customised ILs for biotechnological applications such as protein preservation and customised media for PA dependent reactions such as catalytic reactions.
Original languageEnglish
Pages (from-to)889 - 894
Number of pages6
JournalThe Analyst
Volume140
Issue number3
DOIs
Publication statusPublished - 2015

Cite this

Winther-Jensen, O., Hamilton, J. L., Ng, C. H., Kolodziejczyk, B., & Winther-Jensen, B. (2015). Miniaturisation and simplification of solid-state proton activity sensors for non-aqueous media and ionic liquids. The Analyst, 140(3), 889 - 894. https://doi.org/10.1039/c4an01556h
Winther-Jensen, Orawan ; Hamilton, Jessie L. ; Ng, Chun H. ; Kolodziejczyk, Bartlomiej ; Winther-Jensen, Bjorn. / Miniaturisation and simplification of solid-state proton activity sensors for non-aqueous media and ionic liquids. In: The Analyst. 2015 ; Vol. 140, No. 3. pp. 889 - 894.
@article{32fb7846231847fabf35fff241612687,
title = "Miniaturisation and simplification of solid-state proton activity sensors for non-aqueous media and ionic liquids",
abstract = "This work is the further development of the previous pH (effective) sensor work where a biologically derived proton-active redox centre – riboflavin (RFN) – was entrapped into a vapour phase polymerised poly(3,4- ethylenedioxythiophene) film and ferrocene (Fc) dissolved in the sample solution was used as an internal reference redox couple. Here, we report a disposable solid state pH (effective) sensor where we successfully incorporated both RFN and Fc into a single solid state electrode. The electrodes were then used for pH (effective) sensing where water is not required. The system was further miniaturised and simplified from a 3 electrode to a 2 electrode setup with the working electrode area being as small as 0.09 mm2. The sensors show the ability to measure pH (effective) in both aqueous and non-aqueous media including ionic liquids (ILs) regardless of their hydrophobicity. This is an important step towards the ability to customise ILs or non-aqueous media with suitable proton activity (PA) for various applications e.g. customised ILs for biotechnological applications such as protein preservation and customised media for PA dependent reactions such as catalytic reactions.",
author = "Orawan Winther-Jensen and Hamilton, {Jessie L.} and Ng, {Chun H.} and Bartlomiej Kolodziejczyk and Bjorn Winther-Jensen",
year = "2015",
doi = "10.1039/c4an01556h",
language = "English",
volume = "140",
pages = "889 -- 894",
journal = "The Analyst",
issn = "0003-2654",
publisher = "The Royal Society of Chemistry",
number = "3",

}

Winther-Jensen, O, Hamilton, JL, Ng, CH, Kolodziejczyk, B & Winther-Jensen, B 2015, 'Miniaturisation and simplification of solid-state proton activity sensors for non-aqueous media and ionic liquids', The Analyst, vol. 140, no. 3, pp. 889 - 894. https://doi.org/10.1039/c4an01556h

Miniaturisation and simplification of solid-state proton activity sensors for non-aqueous media and ionic liquids. / Winther-Jensen, Orawan; Hamilton, Jessie L.; Ng, Chun H.; Kolodziejczyk, Bartlomiej; Winther-Jensen, Bjorn.

In: The Analyst, Vol. 140, No. 3, 2015, p. 889 - 894.

Research output: Contribution to journalArticleResearchpeer-review

TY - JOUR

T1 - Miniaturisation and simplification of solid-state proton activity sensors for non-aqueous media and ionic liquids

AU - Winther-Jensen, Orawan

AU - Hamilton, Jessie L.

AU - Ng, Chun H.

AU - Kolodziejczyk, Bartlomiej

AU - Winther-Jensen, Bjorn

PY - 2015

Y1 - 2015

N2 - This work is the further development of the previous pH (effective) sensor work where a biologically derived proton-active redox centre – riboflavin (RFN) – was entrapped into a vapour phase polymerised poly(3,4- ethylenedioxythiophene) film and ferrocene (Fc) dissolved in the sample solution was used as an internal reference redox couple. Here, we report a disposable solid state pH (effective) sensor where we successfully incorporated both RFN and Fc into a single solid state electrode. The electrodes were then used for pH (effective) sensing where water is not required. The system was further miniaturised and simplified from a 3 electrode to a 2 electrode setup with the working electrode area being as small as 0.09 mm2. The sensors show the ability to measure pH (effective) in both aqueous and non-aqueous media including ionic liquids (ILs) regardless of their hydrophobicity. This is an important step towards the ability to customise ILs or non-aqueous media with suitable proton activity (PA) for various applications e.g. customised ILs for biotechnological applications such as protein preservation and customised media for PA dependent reactions such as catalytic reactions.

AB - This work is the further development of the previous pH (effective) sensor work where a biologically derived proton-active redox centre – riboflavin (RFN) – was entrapped into a vapour phase polymerised poly(3,4- ethylenedioxythiophene) film and ferrocene (Fc) dissolved in the sample solution was used as an internal reference redox couple. Here, we report a disposable solid state pH (effective) sensor where we successfully incorporated both RFN and Fc into a single solid state electrode. The electrodes were then used for pH (effective) sensing where water is not required. The system was further miniaturised and simplified from a 3 electrode to a 2 electrode setup with the working electrode area being as small as 0.09 mm2. The sensors show the ability to measure pH (effective) in both aqueous and non-aqueous media including ionic liquids (ILs) regardless of their hydrophobicity. This is an important step towards the ability to customise ILs or non-aqueous media with suitable proton activity (PA) for various applications e.g. customised ILs for biotechnological applications such as protein preservation and customised media for PA dependent reactions such as catalytic reactions.

UR - http://pubs.rsc.org.ezproxy.lib.monash.edu.au/en/journals/journalissues/an#!issueid=an140003&type=current&issnprint=0003-2654

U2 - 10.1039/c4an01556h

DO - 10.1039/c4an01556h

M3 - Article

VL - 140

SP - 889

EP - 894

JO - The Analyst

JF - The Analyst

SN - 0003-2654

IS - 3

ER -