T1 - Low radiation tomographic reconstruction with and without template information
AU - Gopal, Preeti
AU - Chandran, Sharat
AU - Svalbe, Imants
AU - Rajwade, Ajit
PY - 2020/10
Y1 - 2020/10
N2 - Low-dose tomography is highly preferred in medical procedures for its reduced radiation risk when compared to standard-dose Computed Tomography (CT). However, the lower the intensity of X-rays, the higher the acquisition noise and hence the reconstructions suffer from artefacts. A large body of work has focussed on improving the algorithms to minimize these artefacts. In this work, we propose two new techniques, rescaled non-linear least squares and Poisson-Gaussian convolution, that reconstruct the underlying image making use of an accurate or near-accurate statistical model of the noise in the projections. We also propose a reconstruction method when prior knowledge of the underlying object is available in the form of templates. This is applicable to longitudinal studies wherein the same object is scanned multiple times to observe the changes that evolve in it over time. Our results on 3D data show that prior information can be used to compensate for the low-dose artefacts, and we demonstrate that it is possible to simultaneously prevent the prior from adversely biasing the reconstructions of new changes in the test object, by means of careful selection of a weights map, subsequently followed by a method called “re-irradiation”. Additionally, we also present a technique for automated tuning of the regularization parameters for tomographic inversion.
AB - Low-dose tomography is highly preferred in medical procedures for its reduced radiation risk when compared to standard-dose Computed Tomography (CT). However, the lower the intensity of X-rays, the higher the acquisition noise and hence the reconstructions suffer from artefacts. A large body of work has focussed on improving the algorithms to minimize these artefacts. In this work, we propose two new techniques, rescaled non-linear least squares and Poisson-Gaussian convolution, that reconstruct the underlying image making use of an accurate or near-accurate statistical model of the noise in the projections. We also propose a reconstruction method when prior knowledge of the underlying object is available in the form of templates. This is applicable to longitudinal studies wherein the same object is scanned multiple times to observe the changes that evolve in it over time. Our results on 3D data show that prior information can be used to compensate for the low-dose artefacts, and we demonstrate that it is possible to simultaneously prevent the prior from adversely biasing the reconstructions of new changes in the test object, by means of careful selection of a weights map, subsequently followed by a method called “re-irradiation”. Additionally, we also present a technique for automated tuning of the regularization parameters for tomographic inversion.
KW - Compressed sensing
KW - Longitudinal studies
KW - Low-dose tomographic reconstruction
KW - priors
UR - http://www.scopus.com/inward/record.url?scp=85084956928&partnerID=8YFLogxK
U2 - 10.1016/j.sigpro.2020.107582
DO - 10.1016/j.sigpro.2020.107582
M3 - Article
AN - SCOPUS:85084956928
SN - 0165-1684
VL - 175
JO - Signal Processing
JF - Signal Processing
M1 - 107582