Abstract
In this study, an experimental investigation was performed to determine the effect of varying thermoelectric (TEC) cooling power on the solar still using different cover materials. Three types of cover materials, glass, polycarbonate (PC), and acrylic (PMMA), were studied for the TEC cooled solar still. TEC cooling power was varied from 12 W to 36 W by changing the applied TEC current from 2 A to 4 A. The study was conducted at Universiti Malaya, Kuala Lumpur, Malaysia which is located at 3.118∘N latitude and 101.656∘E longitude. The productivity of the solar still productivity with glass cover was increased by up to 76% when TEC cooling used a current of 4 A. The PMMA and PC covers had lower productivity compared to the reference solar still by up to −48% and −82%, respectively. The highest energy efficiency obtained by a solar still with TEC cooling for glass, PC and PMMA cover was 23.6%, 2.5%, and 7.2%, respectively. The average maximum exergy efficiency of solar still with glass, PC, and PMMA cover calculated to be 7.04%, 0.61%, and 2.13%, respectively. The economic analysis revealed that the lowest cost per litre was achieved by glass cover TEC cooling of $ 0.042.
| Original language | English |
|---|---|
| Pages (from-to) | 844-854 |
| Number of pages | 11 |
| Journal | Renewable Energy |
| Volume | 202 |
| DOIs | |
| Publication status | Published - Jan 2023 |
| Externally published | Yes |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Cooling power
- Cover cooling
- Cover material
- Solar still
- Thermoelectric cooling system
Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver