The purpose of this study was to determine the indoor air quality (IAQ) status of an automotive assembly plant in Rawang, Selangor, Malaysia using selected IAQ parameters, such as carbon dioxide (CO 2), carbon monoxide (CO), temperature, relative humidity (RH) and respirable particulate matter (PM10). A cross-sectional study was conducted in the paint shop and body shop sections of the plant in March 2005. The Q-TRAK™Plus IAQ Monitor was used to record the patterns of CO, CO 2, RH and temperature; whilst PM10 was measured using DUSTTRAK™Aerosol Monitor over an 8-hour time weight average (8-TWA). It was found that the average temperatures, RH and PM10 in the paint shop section and body shop sections exceeded the Department of Safety and Health (DOSH) standards. The average concentrations of RH and CO were slightly higher in the body shop section than in the paint shop section, while the average concentrations of temperature and CO 2 were slightly higher in the paint shop section than in the body shop section. There was no difference in the average concentrations of PM10 between the two sections.
| Original language | English |
|---|---|
| Pages (from-to) | 187-192 |
| Number of pages | 6 |
| Journal | Southeast Asian Journal of Tropical Medicine and Public Health |
| Volume | 40 |
| Issue number | 1 |
| Publication status | Published - Jan 2009 |