Improving the mixing process of dry powder inhaler formulations with the iron oxide colour method

Kahlil Desai, Peter Stewart, David Morton, Karen Hapgood

Research output: Chapter in Book/Report/Conference proceedingConference PaperResearch

Abstract

Blending of one or more powders is critical for many pharmaceutical powders, including formulations used for Dry Powder Inhalers. Dry powder inhalers (DPIs) are mixed dry powder medications (asthma) administered via the lungs (pulmonary route). DPIs generally comprise 1% of API and 99% lactose and are mixed in a tumbler mixer or a high shear mixer. Due to empirical nature of commercial production there are production issues such as failed batches, content uniformity issues, and product performance failures, especially low inhalation efficiency values. This leads to production and economic losses but also a lack of understanding in the blending process. The iron oxide colour method (IOCM) is a recent technique that involved mixing 1% of red iron oxide and 99% of lactose in different mixers and observing the colour [1]. The colour of the blend indicates how mixed the blend is; as the mixing time continues the blend colour changes from pink to red to orange; this method helps to understand the mixing process and the quality of mixing. This work follows on with the method by mixing and testing DPI formulations. Actual DPI blends, 99% DPI grade lactose and 1% API (salbutamol sulphate) are mixed in a high shear mixer (1L KG5) and samples are taken for time points of the blend and are checked with their corresponding colour points. This study investigates whether this colour method (IOCM) can predict or determine how much mixing is required for a Dry Powder Inhaler (DPI) blend (lactose/drug) to attain content uniformity (Real standard deviation (RSD) < 5). A High Shear Mixer (HSM) is used to mix DPI blends and samples were taken at different time points for different speeds and the content uniformity was tested. These time points were then compared with their corresponding colour points (lactose/iron oxide) to see if there is a correlation between colour points and content uniformity.

Original languageEnglish
Title of host publicationParticle Technology Forum 2016
Subtitle of host publicationCore Programming Area at the 2016 AiChE Annual Meeting
EditorsChristine Hrenya, Lin Li
Place of PublicationNew York NY USA
PublisherAIChE
Pages224-231
Number of pages8
ISBN (Print)9781510834361
Publication statusPublished - 2016
EventAIChE Annual Meeting 2016 - San Francisco, United States of America
Duration: 13 Nov 201618 Nov 2016

Conference

ConferenceAIChE Annual Meeting 2016
CountryUnited States of America
CitySan Francisco
Period13/11/1618/11/16
OtherPharmaceutical Discovery, Development and Manufacturing Forum 2016 - Core Programming Area at the 2016

Cite this

Desai, K., Stewart, P., Morton, D., & Hapgood, K. (2016). Improving the mixing process of dry powder inhaler formulations with the iron oxide colour method. In C. Hrenya, & L. Li (Eds.), Particle Technology Forum 2016: Core Programming Area at the 2016 AiChE Annual Meeting (pp. 224-231). New York NY USA: AIChE.
Desai, Kahlil ; Stewart, Peter ; Morton, David ; Hapgood, Karen. / Improving the mixing process of dry powder inhaler formulations with the iron oxide colour method. Particle Technology Forum 2016: Core Programming Area at the 2016 AiChE Annual Meeting. editor / Christine Hrenya ; Lin Li. New York NY USA : AIChE, 2016. pp. 224-231
@inproceedings{22106418579747d782554137932a819e,
title = "Improving the mixing process of dry powder inhaler formulations with the iron oxide colour method",
abstract = "Blending of one or more powders is critical for many pharmaceutical powders, including formulations used for Dry Powder Inhalers. Dry powder inhalers (DPIs) are mixed dry powder medications (asthma) administered via the lungs (pulmonary route). DPIs generally comprise 1{\%} of API and 99{\%} lactose and are mixed in a tumbler mixer or a high shear mixer. Due to empirical nature of commercial production there are production issues such as failed batches, content uniformity issues, and product performance failures, especially low inhalation efficiency values. This leads to production and economic losses but also a lack of understanding in the blending process. The iron oxide colour method (IOCM) is a recent technique that involved mixing 1{\%} of red iron oxide and 99{\%} of lactose in different mixers and observing the colour [1]. The colour of the blend indicates how mixed the blend is; as the mixing time continues the blend colour changes from pink to red to orange; this method helps to understand the mixing process and the quality of mixing. This work follows on with the method by mixing and testing DPI formulations. Actual DPI blends, 99{\%} DPI grade lactose and 1{\%} API (salbutamol sulphate) are mixed in a high shear mixer (1L KG5) and samples are taken for time points of the blend and are checked with their corresponding colour points. This study investigates whether this colour method (IOCM) can predict or determine how much mixing is required for a Dry Powder Inhaler (DPI) blend (lactose/drug) to attain content uniformity (Real standard deviation (RSD) < 5). A High Shear Mixer (HSM) is used to mix DPI blends and samples were taken at different time points for different speeds and the content uniformity was tested. These time points were then compared with their corresponding colour points (lactose/iron oxide) to see if there is a correlation between colour points and content uniformity.",
author = "Kahlil Desai and Peter Stewart and David Morton and Karen Hapgood",
year = "2016",
language = "English",
isbn = "9781510834361",
pages = "224--231",
editor = "Christine Hrenya and Lin Li",
booktitle = "Particle Technology Forum 2016",
publisher = "AIChE",
address = "United States of America",

}

Desai, K, Stewart, P, Morton, D & Hapgood, K 2016, Improving the mixing process of dry powder inhaler formulations with the iron oxide colour method. in C Hrenya & L Li (eds), Particle Technology Forum 2016: Core Programming Area at the 2016 AiChE Annual Meeting. AIChE, New York NY USA, pp. 224-231, AIChE Annual Meeting 2016, San Francisco, United States of America, 13/11/16.

Improving the mixing process of dry powder inhaler formulations with the iron oxide colour method. / Desai, Kahlil; Stewart, Peter; Morton, David; Hapgood, Karen.

Particle Technology Forum 2016: Core Programming Area at the 2016 AiChE Annual Meeting. ed. / Christine Hrenya; Lin Li. New York NY USA : AIChE, 2016. p. 224-231.

Research output: Chapter in Book/Report/Conference proceedingConference PaperResearch

TY - GEN

T1 - Improving the mixing process of dry powder inhaler formulations with the iron oxide colour method

AU - Desai, Kahlil

AU - Stewart, Peter

AU - Morton, David

AU - Hapgood, Karen

PY - 2016

Y1 - 2016

N2 - Blending of one or more powders is critical for many pharmaceutical powders, including formulations used for Dry Powder Inhalers. Dry powder inhalers (DPIs) are mixed dry powder medications (asthma) administered via the lungs (pulmonary route). DPIs generally comprise 1% of API and 99% lactose and are mixed in a tumbler mixer or a high shear mixer. Due to empirical nature of commercial production there are production issues such as failed batches, content uniformity issues, and product performance failures, especially low inhalation efficiency values. This leads to production and economic losses but also a lack of understanding in the blending process. The iron oxide colour method (IOCM) is a recent technique that involved mixing 1% of red iron oxide and 99% of lactose in different mixers and observing the colour [1]. The colour of the blend indicates how mixed the blend is; as the mixing time continues the blend colour changes from pink to red to orange; this method helps to understand the mixing process and the quality of mixing. This work follows on with the method by mixing and testing DPI formulations. Actual DPI blends, 99% DPI grade lactose and 1% API (salbutamol sulphate) are mixed in a high shear mixer (1L KG5) and samples are taken for time points of the blend and are checked with their corresponding colour points. This study investigates whether this colour method (IOCM) can predict or determine how much mixing is required for a Dry Powder Inhaler (DPI) blend (lactose/drug) to attain content uniformity (Real standard deviation (RSD) < 5). A High Shear Mixer (HSM) is used to mix DPI blends and samples were taken at different time points for different speeds and the content uniformity was tested. These time points were then compared with their corresponding colour points (lactose/iron oxide) to see if there is a correlation between colour points and content uniformity.

AB - Blending of one or more powders is critical for many pharmaceutical powders, including formulations used for Dry Powder Inhalers. Dry powder inhalers (DPIs) are mixed dry powder medications (asthma) administered via the lungs (pulmonary route). DPIs generally comprise 1% of API and 99% lactose and are mixed in a tumbler mixer or a high shear mixer. Due to empirical nature of commercial production there are production issues such as failed batches, content uniformity issues, and product performance failures, especially low inhalation efficiency values. This leads to production and economic losses but also a lack of understanding in the blending process. The iron oxide colour method (IOCM) is a recent technique that involved mixing 1% of red iron oxide and 99% of lactose in different mixers and observing the colour [1]. The colour of the blend indicates how mixed the blend is; as the mixing time continues the blend colour changes from pink to red to orange; this method helps to understand the mixing process and the quality of mixing. This work follows on with the method by mixing and testing DPI formulations. Actual DPI blends, 99% DPI grade lactose and 1% API (salbutamol sulphate) are mixed in a high shear mixer (1L KG5) and samples are taken for time points of the blend and are checked with their corresponding colour points. This study investigates whether this colour method (IOCM) can predict or determine how much mixing is required for a Dry Powder Inhaler (DPI) blend (lactose/drug) to attain content uniformity (Real standard deviation (RSD) < 5). A High Shear Mixer (HSM) is used to mix DPI blends and samples were taken at different time points for different speeds and the content uniformity was tested. These time points were then compared with their corresponding colour points (lactose/iron oxide) to see if there is a correlation between colour points and content uniformity.

UR - http://www.scopus.com/inward/record.url?scp=85019033337&partnerID=8YFLogxK

M3 - Conference Paper

SN - 9781510834361

SP - 224

EP - 231

BT - Particle Technology Forum 2016

A2 - Hrenya, Christine

A2 - Li, Lin

PB - AIChE

CY - New York NY USA

ER -

Desai K, Stewart P, Morton D, Hapgood K. Improving the mixing process of dry powder inhaler formulations with the iron oxide colour method. In Hrenya C, Li L, editors, Particle Technology Forum 2016: Core Programming Area at the 2016 AiChE Annual Meeting. New York NY USA: AIChE. 2016. p. 224-231