TY - JOUR
T1 - Fast algorithms for the analysis of sino-atrial node function
AU - Jones, Michael Emlyn
AU - Heddle, William F.
AU - Tonkin, Andrew Maxwell
PY - 1985/1
Y1 - 1985/1
N2 - The calculations of parameters of the sino-atrial node function have previously required the application of a non-linear least squares curve-fitting algorithm. We have compared five algorithms, three of which eliminate the need for direct non-linear least squares routines. The fast algorithms can provide greater accuracy while using less than 10% of the computing time. They make it feasible to provide real-time analysis during clinical electrophysiological studies.
AB - The calculations of parameters of the sino-atrial node function have previously required the application of a non-linear least squares curve-fitting algorithm. We have compared five algorithms, three of which eliminate the need for direct non-linear least squares routines. The fast algorithms can provide greater accuracy while using less than 10% of the computing time. They make it feasible to provide real-time analysis during clinical electrophysiological studies.
UR - http://www.scopus.com/inward/record.url?scp=0021962827&partnerID=8YFLogxK
U2 - 10.1016/0020-7101(85)90041-8
DO - 10.1016/0020-7101(85)90041-8
M3 - Article
C2 - 3838537
AN - SCOPUS:0021962827
SN - 0020-7101
VL - 16
SP - 9
EP - 16
JO - International Journal of Bio-Medical Computing
JF - International Journal of Bio-Medical Computing
IS - 1
ER -