TY - JOUR
T1 - Experimental study of CFDST columns infilled with UHPC under close-range blast loading
AU - Zhang, Fangrui
AU - Wu, Chengqing
AU - Zhao, Xiao-Ling
AU - Xiang, Hengbo
AU - Li, Zhong Xian
AU - Fang, Qin
AU - Liu, Zhongxian
AU - Zhang, Yadong
AU - Heidarpour, Amin
AU - Packer, Jeffrey A.
PY - 2016/7/1
Y1 - 2016/7/1
N2 - Concrete-filled double-skin tubes (CFDST) have been increasingly popular in the field of engineering in recent years. A lot of research has been carried out to investigate the behaviour of CFDST members under a variety of loading conditions. This paper presents an experimental investigation on ultra-high performance concrete infilled double-skin tube columns subjected to close-in blast loading. Two types of CFDST columns were investigated in the experiments - one with both inner and outer tubes circular and the other one with both square. The main test parameters included the explosive charge weight and the magnitude of axial load. After the blast tests, there was no visible buckling nor ruptures found on the steel tubes and only minor cracks, of no more than 1mm width, were observed in the core concrete when the outer steel tube was removed. Based on the findings of the experiments, it is evident that CFDST column has excellent blast resistance. This feature has the potential to be used in high-value structures which may be the targets of terrorist attacks, such as embassies, government buildings and critical infrastructures.
AB - Concrete-filled double-skin tubes (CFDST) have been increasingly popular in the field of engineering in recent years. A lot of research has been carried out to investigate the behaviour of CFDST members under a variety of loading conditions. This paper presents an experimental investigation on ultra-high performance concrete infilled double-skin tube columns subjected to close-in blast loading. Two types of CFDST columns were investigated in the experiments - one with both inner and outer tubes circular and the other one with both square. The main test parameters included the explosive charge weight and the magnitude of axial load. After the blast tests, there was no visible buckling nor ruptures found on the steel tubes and only minor cracks, of no more than 1mm width, were observed in the core concrete when the outer steel tube was removed. Based on the findings of the experiments, it is evident that CFDST column has excellent blast resistance. This feature has the potential to be used in high-value structures which may be the targets of terrorist attacks, such as embassies, government buildings and critical infrastructures.
KW - Blast loading
KW - Columns
KW - Concrete-filled double-skin tubes
KW - Ultra-high-performance concrete
UR - https://www.scopus.com/pages/publications/84962287993
U2 - 10.1016/j.ijimpeng.2016.01.011
DO - 10.1016/j.ijimpeng.2016.01.011
M3 - Article
AN - SCOPUS:84962287993
SN - 0734-743X
VL - 93
SP - 184
EP - 195
JO - International Journal of Impact Engineering
JF - International Journal of Impact Engineering
ER -