Experimental and thermal analysis of washing the packed ice bed in wash columns

Frank G F Qin, Min Lin Yang, Xiao Xi Yang, Xiao Dong Chen, Arjan Abeynaike

Research output: Contribution to journalArticleResearchpeer-review

14 Citations (Scopus)

Abstract

In the process of freeze concentration (FC), the main problems in operating the counter-current wash column used for separating ice from ice slurries are channeling and viscous fingering. These phenomena lead to the mixing of pure water and mother liquid, as well as entrainment of mother liquid within the removed ice. Experimental and thermal analysis of the wash front interface in this research relates ice melting and wash front breakthrough with the operating conditions (such as the wash water temperature, ice bed temperature and porosity). Criteria for wash front stability are proposed.
Original languageEnglish
Pages (from-to)2835 - 2847
Number of pages13
JournalAIChE Journal
Volume55
Issue number11
DOIs
Publication statusPublished - 2009