TY - JOUR
T1 - Evaluation of aneurysm rupture risk based upon flowrate-independent hemodynamic parameters
T2 - A multi-center pilot study
AU - Zhang, Mingzi
AU - Hou, Xiaoxi
AU - Qian, Yi
AU - Chong, Winston
AU - Zhang, Xin
AU - Duan, Chuan Zhi
AU - Ou, Chubin
N1 - Publisher Copyright:
© Author(s) (or their employer(s)) 2022. No commercial re-use. See rights and permissions. Published by BMJ.
PY - 2023/7
Y1 - 2023/7
N2 - Background: Specifying generic flow boundary conditions in aneurysm hemodynamic simulations yields a great degree of uncertainty for the evaluation of aneurysm rupture risk. Herein, we proposed the use of flowrate-independent parameters in discriminating unstable aneurysms and compared their prognostic performance against that of conventional absolute parameters. Methods: This retrospective study included 186 aneurysms collected from three international centers, with the stable aneurysms having a minimum follow-up period of 24 months. The flowrate-independent aneurysmal wall shear stress (WSS) and energy loss (EL) were defined as the coefficients of the second-order polynomials characterizing the relationships between the respective parameters and the parent-artery flows. Performance of the flowrate-independent parameters in discriminating unstable aneurysms with the logistic regression, Adaboost, and support-vector machine (SVM) methods was quantified and compared against that of the conventional parameters, in terms of sensitivity, specificity, and area under the curve (AUC). Results: In discriminating unstable aneurysms, the proposed flowrate-independent EL achieved the highest sensitivity (0.833, 95% CI 0.586 to 0.964) and specificity (0.833, 95% CI 0.672 to 0.936) on the SVM, with the AUC outperforming the conventional EL by 0.133 (95% CI 0.039 to 0.226, p=0.006). Likewise, the flowrate-independent WSS outperformed the conventional WSS in terms of the AUC (difference: 0.137, 95% CI 0.033 to 0.241, p=0.010). Conclusion: The flowrate-independent hemodynamic parameters surpassed their conventional counterparts in predicting the stability of aneurysms, which may serve as a promising set of hemodynamic metrics to be used for the prediction of aneurysm rupture risk when physiologically real vascular boundary conditions are unavailable.
AB - Background: Specifying generic flow boundary conditions in aneurysm hemodynamic simulations yields a great degree of uncertainty for the evaluation of aneurysm rupture risk. Herein, we proposed the use of flowrate-independent parameters in discriminating unstable aneurysms and compared their prognostic performance against that of conventional absolute parameters. Methods: This retrospective study included 186 aneurysms collected from three international centers, with the stable aneurysms having a minimum follow-up period of 24 months. The flowrate-independent aneurysmal wall shear stress (WSS) and energy loss (EL) were defined as the coefficients of the second-order polynomials characterizing the relationships between the respective parameters and the parent-artery flows. Performance of the flowrate-independent parameters in discriminating unstable aneurysms with the logistic regression, Adaboost, and support-vector machine (SVM) methods was quantified and compared against that of the conventional parameters, in terms of sensitivity, specificity, and area under the curve (AUC). Results: In discriminating unstable aneurysms, the proposed flowrate-independent EL achieved the highest sensitivity (0.833, 95% CI 0.586 to 0.964) and specificity (0.833, 95% CI 0.672 to 0.936) on the SVM, with the AUC outperforming the conventional EL by 0.133 (95% CI 0.039 to 0.226, p=0.006). Likewise, the flowrate-independent WSS outperformed the conventional WSS in terms of the AUC (difference: 0.137, 95% CI 0.033 to 0.241, p=0.010). Conclusion: The flowrate-independent hemodynamic parameters surpassed their conventional counterparts in predicting the stability of aneurysms, which may serve as a promising set of hemodynamic metrics to be used for the prediction of aneurysm rupture risk when physiologically real vascular boundary conditions are unavailable.
KW - Aneurysm
KW - Blood Flow
KW - Stroke
KW - Technology
UR - https://www.scopus.com/pages/publications/85132378929
U2 - 10.1136/neurintsurg-2022-018691
DO - 10.1136/neurintsurg-2022-018691
M3 - Article
C2 - 35688619
AN - SCOPUS:85132378929
SN - 1759-8478
VL - 15
SP - 695
EP - 700
JO - Journal of NeuroInterventional Surgery
JF - Journal of NeuroInterventional Surgery
IS - 7
ER -