T1 - Evaluation of an in vitro coronary stent thrombosis model for preclinical assessment
AU - Perry-Nguyen, Dylan
AU - Jung, Richard G.
AU - Labinaz, Alisha
AU - Duchez, Anne-Claire
AU - Dewidar, Omar
AU - Simard, Trevor
AU - Karunakaran, Denuja
AU - Majeed, Kamran
AU - Sarathy, Kiran
AU - Li, Ruonan
AU - Ramirez, F. Daniel
AU - Di Santo, Pietro
AU - Rochman, Rebecca
AU - So, Derek
AU - Foin, Nicolas
AU - Hibbert, Benjamin
PY - 2019/4
Y1 - 2019/4
N2 - Stent thrombosis remains an infrequent but significant complication following percutaneous coronary intervention. Preclinical models to rapidly screen and validate therapeutic compounds for efficacy are lacking. Herein, we describe a reproducible, high throughput and cost-effective method to evaluate candidate therapeutics and devices for either treatment or propensity to develop stent thrombosis in an in vitro bench-top model. Increasing degree of stent malapposition (0.00 mm, 0.10 mm, 0.25 mm and 0.50 mm) was associated with increasing thrombosis and luminal area occlusion (4.1 ± 0.5%, 6.3 ± 0.5%, 19.7 ± 4.5%, and 92.6 ± 7.4%, p < 0.0001, respectively). Differences in stent design in the form of bare-metal, drug-eluting, and bioresorbable vascular scaffolds demonstrated differences in stent thrombus burden (14.7 ± 3.8% vs. 20.5 ± 3.1% vs. 86.8 ± 5.3%, p < 0.01, respectively). Finally, thrombus burden was significantly reduced when healthy blood samples were incubated with Heparin, ASA/Ticagrelor (DAPT), and Heparin+DAPT compared to control (DMSO) at 4.1 ± 0.6%, 6.9 ± 1.7%, 4.5 ± 1.2%, and 12.1 ± 1.8%, respectively (p < 0.01). The reported model produces high throughput reproducible thrombosis results across a spectrum of antithrombotic agents, stent design, and degrees of apposition. Importantly, performance recapitulates clinical observations of antiplatelet/antithrombotic regimens as well as device and deployment characteristics. Accordingly, this model may serve as a screening tool for candidate therapies in preclinical evaluation.
AB - Stent thrombosis remains an infrequent but significant complication following percutaneous coronary intervention. Preclinical models to rapidly screen and validate therapeutic compounds for efficacy are lacking. Herein, we describe a reproducible, high throughput and cost-effective method to evaluate candidate therapeutics and devices for either treatment or propensity to develop stent thrombosis in an in vitro bench-top model. Increasing degree of stent malapposition (0.00 mm, 0.10 mm, 0.25 mm and 0.50 mm) was associated with increasing thrombosis and luminal area occlusion (4.1 ± 0.5%, 6.3 ± 0.5%, 19.7 ± 4.5%, and 92.6 ± 7.4%, p < 0.0001, respectively). Differences in stent design in the form of bare-metal, drug-eluting, and bioresorbable vascular scaffolds demonstrated differences in stent thrombus burden (14.7 ± 3.8% vs. 20.5 ± 3.1% vs. 86.8 ± 5.3%, p < 0.01, respectively). Finally, thrombus burden was significantly reduced when healthy blood samples were incubated with Heparin, ASA/Ticagrelor (DAPT), and Heparin+DAPT compared to control (DMSO) at 4.1 ± 0.6%, 6.9 ± 1.7%, 4.5 ± 1.2%, and 12.1 ± 1.8%, respectively (p < 0.01). The reported model produces high throughput reproducible thrombosis results across a spectrum of antithrombotic agents, stent design, and degrees of apposition. Importantly, performance recapitulates clinical observations of antiplatelet/antithrombotic regimens as well as device and deployment characteristics. Accordingly, this model may serve as a screening tool for candidate therapies in preclinical evaluation.
KW - Antiplatelet agents
KW - methods
KW - optical coherence tomography
KW - percutaneous coronary intervention
KW - stent thrombosis
UR - https://www.scopus.com/pages/publications/85064194062
U2 - 10.1080/09537104.2019.1595564
DO - 10.1080/09537104.2019.1595564
M3 - Article
AN - SCOPUS:85064194062
SN - 0953-7104
VL - 31
SP - 167
EP - 173
JO - Platelets
JF - Platelets
IS - 2
ER -