TY - JOUR
T1 - Endovascular Treatment of Intracranial Aneurysms Using the Novel Low Profile Visualized Intraluminal Support EVO Stent
T2 - Multicenter Early Feasibility Experience
AU - Foo, Michelle
AU - Maingard, Julian
AU - Hall, Jonathan
AU - Ren, Yifan
AU - Mitreski, Goran
AU - Slater, Lee Anne
AU - Chandra, Ronil
AU - Chong, Winston
AU - Jhamb, Ashu
AU - Russell, Jeremy
AU - Kok, Hong Kuan
AU - Brooks, Mark
AU - Asadi, Hamed
N1 - Publisher Copyright:
© 2021. Korean Society of Interventional Neuroradiology.
PY - 2021/7
Y1 - 2021/7
N2 - Purpose: Low-profile, self-expandable stents have broadened therapeutic options available for definitive treatment of intracranial aneurysms. The novel Low-Profile Visualized Intraluminal Support (LVIS) EVO stent extends upon the success of its predecessor, the LVIS Jr stent, aiming to enable higher visibility and greater opening ability within a self-expandable and fully retrievable microstent system. In this study, we aim to report the early safety and feasibility experience with the LVIS EVO stent. Materials and Methods: A multicenter, retrospective, observational study was conducted on patients who had intracranial aneurysms treated with the LVIS EVO stent across 3 Australian neurovascular centers between February 2020 and September 2020. Short-term technical and clinical outcomes were evaluated. Results: A total of 22 LVIS EVO stents were successfully implanted to treat 15 aneurysms (3 ruptured, 12 unruptured) in 15 patients. Aneurysms ranged from 2 mm to 35 mm in dome height. The LVIS EVO stent was used for stent-assisted coiling in 11 patients and flow diversion in 4 patients. There were no device-related procedural complications. There were 2 cases of peri-procedural symptomatic thromboembolic complications and no procedure-related mortality. At early radiological follow up, 10 patients had complete occlusion, 4 patients had small neck remnants, and 1 patient who was managed with flow diversion had a residual aneurysm. Conclusion: Early experience with the LVIS EVO stent demonstrated safety and feasibility for stent-assisted coiling as well as flow diversion for intracranial aneurysms. In this heterogeneous cohort, including ruptured, complex, and large aneurysms, all cases were technically successful.
AB - Purpose: Low-profile, self-expandable stents have broadened therapeutic options available for definitive treatment of intracranial aneurysms. The novel Low-Profile Visualized Intraluminal Support (LVIS) EVO stent extends upon the success of its predecessor, the LVIS Jr stent, aiming to enable higher visibility and greater opening ability within a self-expandable and fully retrievable microstent system. In this study, we aim to report the early safety and feasibility experience with the LVIS EVO stent. Materials and Methods: A multicenter, retrospective, observational study was conducted on patients who had intracranial aneurysms treated with the LVIS EVO stent across 3 Australian neurovascular centers between February 2020 and September 2020. Short-term technical and clinical outcomes were evaluated. Results: A total of 22 LVIS EVO stents were successfully implanted to treat 15 aneurysms (3 ruptured, 12 unruptured) in 15 patients. Aneurysms ranged from 2 mm to 35 mm in dome height. The LVIS EVO stent was used for stent-assisted coiling in 11 patients and flow diversion in 4 patients. There were no device-related procedural complications. There were 2 cases of peri-procedural symptomatic thromboembolic complications and no procedure-related mortality. At early radiological follow up, 10 patients had complete occlusion, 4 patients had small neck remnants, and 1 patient who was managed with flow diversion had a residual aneurysm. Conclusion: Early experience with the LVIS EVO stent demonstrated safety and feasibility for stent-assisted coiling as well as flow diversion for intracranial aneurysms. In this heterogeneous cohort, including ruptured, complex, and large aneurysms, all cases were technically successful.
KW - Endovascular techniques
KW - Interventional radiology instrumentation
KW - Intracranial aneurysm
KW - Neuroimaging
UR - https://www.scopus.com/pages/publications/85125096812
U2 - 10.5469/neuroint.2021.00199
DO - 10.5469/neuroint.2021.00199
M3 - Article
C2 - 34139794
AN - SCOPUS:85125096812
SN - 2093-9043
VL - 16
SP - 122
EP - 131
JO - Neurointervention
JF - Neurointervention
IS - 2
ER -