Abstract
This paper reports the complication of early incisional hernia occurring in three patients at the site of entry of a 12 mm disposable port during laparoscopic surgery. To avoid this complication, it is recommended that a 12 mm port be introduced through muscle rather than fascia and, following its removal, the defect in the abdominal wall be closed by sutures.
| Original language | English |
|---|---|
| Pages (from-to) | 574-575 |
| Number of pages | 2 |
| Journal | Australian and New Zealand Journal of Surgery |
| Volume | 63 |
| Issue number | 7 |
| DOIs | |
| Publication status | Published - 1 Jan 1993 |
Keywords
- early incisional hernia
- laparoscopic surgery.