TY - JOUR
T1 - Dryout analysis of overloaded microscale capillary-driven two-phase heat transfer devices
AU - Gan, Jie Sheng
AU - Sia, Tong Seng
AU - Hung, Yew Mun
AU - Chin, Jit Kai
N1 - Funding Information:
This work was supported by the ( 04-02-10-SF0113 ) eScienceFund, Ministry of Science, Technology and Innovation (MOSTI), Malaysia .
Publisher Copyright:
© 2016.
Copyright:
Copyright 2016 Elsevier B.V., All rights reserved.
PY - 2016/8
Y1 - 2016/8
N2 - Dryout occurrence at high heat input is one of the detrimental factors that limit the thermal efficiency of a phase-change heat transfer device. In this work, we demonstrate that by employing visualization method, the dryout occurrence of an elongated liquid droplet in a transparent evacuated microscale two-phase flow device can be scrutinized. The circulation of liquid from the condenser to the evaporator is driven by the capillary action which is the primary limitation that governs the maximum heat transport capability of the device. When the evaporation rate exceeds the circulation rate of condensate, dryout will take place in the evaporator end. The propagation of dryout lengths can be accurately determined directly from visualization and a more accurate evaluation of the dryout length compared to the conventional method by measuring the axial temperatures has been developed. By quantifying the performance indicators of the cooling device over a wide range of operating conditions, including the underloaded and overloaded operations, the observation of dryout occurrence in this study correlates highly with the anticipated heat transfer characteristics of a phase-change heat transfer device. This study provides essential insights, particularly on the overloaded conditions, to the design of a microscale two-phase heat transfer device.
AB - Dryout occurrence at high heat input is one of the detrimental factors that limit the thermal efficiency of a phase-change heat transfer device. In this work, we demonstrate that by employing visualization method, the dryout occurrence of an elongated liquid droplet in a transparent evacuated microscale two-phase flow device can be scrutinized. The circulation of liquid from the condenser to the evaporator is driven by the capillary action which is the primary limitation that governs the maximum heat transport capability of the device. When the evaporation rate exceeds the circulation rate of condensate, dryout will take place in the evaporator end. The propagation of dryout lengths can be accurately determined directly from visualization and a more accurate evaluation of the dryout length compared to the conventional method by measuring the axial temperatures has been developed. By quantifying the performance indicators of the cooling device over a wide range of operating conditions, including the underloaded and overloaded operations, the observation of dryout occurrence in this study correlates highly with the anticipated heat transfer characteristics of a phase-change heat transfer device. This study provides essential insights, particularly on the overloaded conditions, to the design of a microscale two-phase heat transfer device.
KW - Capillary-driven flow
KW - Dryout length
KW - Flow visualization
KW - Phase-change heat transfer
UR - http://www.scopus.com/inward/record.url?scp=84969920271&partnerID=8YFLogxK
U2 - 10.1016/j.icheatmasstransfer.2016.05.027
DO - 10.1016/j.icheatmasstransfer.2016.05.027
M3 - Article
AN - SCOPUS:84969920271
VL - 76
SP - 162
EP - 170
JO - International Communications in Heat and Mass Transfer
JF - International Communications in Heat and Mass Transfer
SN - 0735-1933
ER -