TY - JOUR
T1 - Cost-Effectiveness of Transcatheter Versus Surgical Aortic Valve Replacement in Low-Risk Patients With Severe Aortic Stenosis
AU - Zhou, Jennifer Y.
AU - Liew, Danny
AU - Duffy, Stephen J.
AU - Walton, Antony
AU - Htun, Nay
AU - Stub, Dion
N1 - Funding Information:
Associate Professor Dion Stub's research is supported by the National Heart Foundation of Australia Fellowship and the Viertel Charitable Foundation Award. Professor Stephen J. Duffy’s work is supported by a National Health and Medical Research Council of Australia grant. A/Prof Antony Walton’s research is supported by the Edwards Fellowship.
Funding Information:
Associate Professor Dion Stub's research is supported by the National Heart Foundation of Australia Fellowship and the Viertel Charitable Foundation Award. Professor Stephen J. Duffy's work is supported by a National Health and Medical Research Council of Australia grant. A/Prof Antony Walton's research is supported by the Edwards Fellowship.
Publisher Copyright:
© 2020 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ)
PY - 2021/4
Y1 - 2021/4
N2 - Background: Recent studies have shown that transcatheter aortic valve implantation (TAVI) is non-inferior to surgical aortic valve replacement (SAVR) for treatment of low-risk patients with severe aortic stenosis (AS). However, the cost-effectiveness of TAVI in this population is unknown. We sought to evaluate the cost-effectiveness of both balloon-expandable and self-expanding TAVI compared to SAVR in patients with severe AS at low operative risk. Methods: We developed a Markov model comparing TAVI to SAVR over a lifetime horizon. Key data inputs were drawn from the Placement of AoRTic TraNscathetER Valve (PARTNER) 3 trial for balloon-expandable TAVI and the Evolut Low-Risk trial for self-expanding TAVI. Costs were obtained from Australian sources. The perspective was that of the Australian health care system. Results: Although procedural costs were higher for TAVI compared to SAVR, these were offset by a shorter length of hospitalisation and lower acute complication costs in the TAVI group. Over a lifetime horizon, balloon-expandable TAVI was associated with increased costs of A$702 compared to SAVR, and increased quality-adjusted survival by 0.20 years, yielding an incremental cost-effectiveness ratio of A$3,521 per quality-adjusted life year (QALY) saved. Self-expanding TAVI was associated with lower lifetime costs compared to SAVR, and increased quality-adjusted survival by 0.08 years, and was therefore economically dominant. In probabilistic sensitivity analyses, balloon-expandable TAVI was cost-effective in 78% of iterations (at a cost-effectiveness threshold of A$50,000 per QALY gained) and self-expanding TAVI was cost-effective in 70% of iterations. Conclusions: Among low-risk AS patients, both balloon-expandable and self-expanding TAVI are likely to be cost-effective relative to SAVR.
AB - Background: Recent studies have shown that transcatheter aortic valve implantation (TAVI) is non-inferior to surgical aortic valve replacement (SAVR) for treatment of low-risk patients with severe aortic stenosis (AS). However, the cost-effectiveness of TAVI in this population is unknown. We sought to evaluate the cost-effectiveness of both balloon-expandable and self-expanding TAVI compared to SAVR in patients with severe AS at low operative risk. Methods: We developed a Markov model comparing TAVI to SAVR over a lifetime horizon. Key data inputs were drawn from the Placement of AoRTic TraNscathetER Valve (PARTNER) 3 trial for balloon-expandable TAVI and the Evolut Low-Risk trial for self-expanding TAVI. Costs were obtained from Australian sources. The perspective was that of the Australian health care system. Results: Although procedural costs were higher for TAVI compared to SAVR, these were offset by a shorter length of hospitalisation and lower acute complication costs in the TAVI group. Over a lifetime horizon, balloon-expandable TAVI was associated with increased costs of A$702 compared to SAVR, and increased quality-adjusted survival by 0.20 years, yielding an incremental cost-effectiveness ratio of A$3,521 per quality-adjusted life year (QALY) saved. Self-expanding TAVI was associated with lower lifetime costs compared to SAVR, and increased quality-adjusted survival by 0.08 years, and was therefore economically dominant. In probabilistic sensitivity analyses, balloon-expandable TAVI was cost-effective in 78% of iterations (at a cost-effectiveness threshold of A$50,000 per QALY gained) and self-expanding TAVI was cost-effective in 70% of iterations. Conclusions: Among low-risk AS patients, both balloon-expandable and self-expanding TAVI are likely to be cost-effective relative to SAVR.
KW - Aortic stenosis
KW - Cost-effectiveness
KW - Transcatheter aortic valve implantation
UR - https://www.scopus.com/pages/publications/85096139703
U2 - 10.1016/j.hlc.2020.09.934
DO - 10.1016/j.hlc.2020.09.934
M3 - Article
C2 - 33189571
AN - SCOPUS:85096139703
SN - 1443-9506
VL - 30
SP - 547
EP - 554
JO - Heart Lung and Circulation
JF - Heart Lung and Circulation
IS - 4
ER -