Skip to main navigation Skip to search Skip to main content

Complete coverage fouling model for constant flux crossflow ultrafiltration and experimental validation

  • Yu-Heng Cheng
  • , Alon Y. Kirschner
  • , Jun Jie Wu
  • , Mostafa Nassr
  • , William A. Sullivan
  • , Donald R. Paul
  • , Lynn E. Katz
  • , Robert W. Field
  • , Benny D. Freeman

Research output: Contribution to journal › Article › Research › peer-review

Abstract

A complete coverage model is proposed to describe fouling in constant flux crossflow ultrafiltration. Constant flux crossflow fouling experiments were conducted using dilute latex bead suspensions and commercial poly(ether sulfone) flat sheet ultrafiltration membranes to investigate the influence of operating conditions on evolution of transmembrane pressure (ΔP, TMP) with time. Changes in permeate flux or crossflow rate had little influence on the normalized TMP profile at high latex bead concentration (i.e., above 25 ppm) because the membrane surface was covered with latex beads. At low concentration (i.e., below 25 ppm), increases in permeate flux or foulant concentration increased normalized ΔP. However, this increase in normalized ΔP with permeate flux or foulant concentration diminishes when the permeate flux/concentration is high enough to overwhelm particle removal due to crossflow. These results are in good agreement with the new complete coverage model which describes the influence of operating parameters on fouling better than the previous model.

Original languageEnglish
Article number124132
Number of pages12
JournalJournal of Membrane Science
Volume729
DOIs
Publication statusPublished - Jun 2025
Externally publishedYes

Keywords

  • Constant flux
  • Crossflow
  • Fouling model
  • Ultrafiltration

Cite this