Abstract
Background: Management of coronary artery fistula (CAF) is based on obliterating the fistula communication between the cardiac arteries and other thoracic vessels. Case presentation: We describe the presentation of an 85-year-old female with progressive exertional dyspnea on a background of a long standing left anterior descending diagonal to pulmonary artery fistula. We utilized neuro-interventional techniques to perform coil embolization via use of a Scepter XC dual lumen micro catheter. Conclusions: Dual lumen balloon catheters allow for super-selective artery interrogation, stability of balloon positioning, with less trauma to vessel architecture and accurate embolization. There were no complications and the patient reported improvement of symptoms on review.
Original language | English |
---|---|
Article number | 83 |
Number of pages | 5 |
Journal | CVIR Endovascular |
Volume | 3 |
Issue number | 1 |
DOIs | |
Publication status | Published - Dec 2020 |
Keywords
- Coronary vessel anomaly
- Embolization
- Endovascular
- Fistula
- Microcatheter
- Percutaneous cardiac intervention
- Radiology